Progrmaming For The Remote Keyswitch - ADEMCO Vista-20 Installation Instructions Manual

Hide thumbs Also See for Vista-20:
Table of Contents

Advertisement

RosI--@3
For
me
n-o~e
K-*
1. With at least one 2-line Alpha keypad (5137AD or 6139) comected to the
Partition 1 terminals, power up the system. If you had previously
connectedthe AC transformer to the controlpanel, you need only plug in
the transformer (to 120VAC outlet)to powerup the system.
2.
Enter the programming mode by enter@
Installer code (411 2) + 8 + O + O keys.
Note: If keyswitchis enabled, in menu mode *56 the Zone Type (ZT) for
zone 7 will show"77", and will not be accessible for programming.
3.
press m.
Note that this is an interactive programming mode. You will use it to
program zone 7 for partition number, alarm report codes,and to progmm
responsetime (zone@pe will automaticallyshow as "77").
II
Enter Zn Num.
(00 = Quit)
07
II
Zone
Number~
Micals~
display
II
ZnZTPRCln
RT
07771
00HW1
u
J ZoneNumber
II
07 Zone Type
77
II
Zone
Type
T
II 07 Partition
II
Upon entering *56 mode,this prompt will be
displayed.
Enter zone number "07" (if not already
present).
Following this entry, press*to continue.
A summary display will appear,showing the
presentstatus of zone 7'sprogramming.
Zn = zonenumbezy
ZT = zone type;
P = partition to which zone is assigned;
RC = report codefor that zone;
In= input @pe of zone;
RT = responsetime for that zone.
Values displayed are the factorydefaults for
zone 7 or, if this is not a new installation,
they are the currently programmedvalues.
To program zone
7, press
[*I.
Zone type will be automaticallydisplayed as
'77", and
no entry
is required.
I%SS [*I to continue.
The partition to which the keyswitch is
assignedis enteredhere. Enter "l" or "2. Note
thatthe
Keyswitch arming may only be wsed in
one partition.
(Default= [11.
Press [*I to continue.
p7z7i5q
The report code consists of 2 hexadecimal
digits,
;ach in turn
consistingof
2 numerical
digits. For example,for a report codeof "3C,
enter [01[3]for "3" and [1][2] for "C".
If necessary,refer to
Section 17. SYSTEM
COMMUNICATION
for completeinforma-
tion on report codes.
Enter the desired numbers and then press
~
[*] to continue.