*27
POWERIJNE
CARRIER DEVICE (X-1O) HOUSE ID
Powerline Carrier devicesrequire a House ID. This field identifies
this houseID to the control.
If PowerlineCarrier devices are used, they are selected in field * 80.
House ID is enteredin followingmanner:
0= A,1=B,2=C,
3= D,4=E,5=F,
6= G,7=H,8=I,9=J,
#+10=
~#+ll=L,
#+12=
M,#+
13= N,#+14=0,
#+15=P.
Default is O.
*28
VOICE MODULE
PHONE CODE
m
The use of a 4285 Voice Module (can be used in Partition 1 only)
requires a 2-digit code.
Enter a 2-digit phone access codeas follows: For first digit, enter
any any digit from 1 to 9; for second digit, enter # +11 for "*", or
# +12 for "#".
ExampZe:
If desired access codeis 7*, 7 is the first entry, and # + 11
(for *) is the secondentry.
*9
OUTPUT TO LONG RANGE RADIO
(No. 7720 PLUW7820)
If output to LR.R is selected here, all messagesthat are programmed
to go to the primary telephoneline receiver wiIl also be sent to the
7720 PLUS or 7820 radio. Thesemessageswill always be in Contact
ID format (not affected by entry in field *48). The data line is
supervised
as well
as certain
functions
in
the
radio.
If
communication is lost or a trouble develops, a message will be
attempted to be sent via both radio and telephone to the central
station.
Note:
Normal trouble restorereport (*71) is sent on restore of the
condition.
Entry is first digit of Trouble Dialer Repo~ enter Trouble code 1-9,
B (# +11), C (# +12), D (# +13), E (# +14), or F (# +15). The 2nd digit
of Trouble Dizder Report is automatically the 2nd digit fkom field
*60. For
UL
installations,
Long
Range
Radio
must
be
disabled (enter "O").
Note: The Radio should be programmed for deviceaddress 3 on the
keypad lines.
*3O
KEYSWITCH
ENABLE
•1
This field must be enabled (enter 1) if using a keyswitch. The
keyswitchmust be connected to zone 7, which can then not be used
for any other purpose. Default is O (no keyswitch).
If keyswitchis enabled,in menu
mode
*56 the
Zone me
(ZT)
for
'zone 7 will show "77", and the zone will not be accessiblefor
programming.
If the 4146 kewnvitch is used
with onlv
Red and Green LEDs
connected(no iock switch and tamper
&tch)
to
simply provide
an armingkeady
status indicator
panel, zone 7 can then be used
as a
hard-wired protectionzone, provided
you do not enable
this field.
ZONE SOUNDS AND
*32
SINGLE ALARM SOUNDING PER ZONE
(per armed period)
(*=:
This
field limits alarm sounding to once per arming period for a given
zone.
Enter 1 for yes; default is
O
(no). Enter
60-
for
UL
installations.
*33
FIRE SOUNDER
TIMEOUT
•1
This
field determineswhether the external sounder will shut off after
time allotted, or continue until manually turned off. Enter O for
soundertimeout, or
1
for no timeout. Default is O.
Enter '@B for UL installations.