Rogrammm - g
Wined
E xpansion
zones
1. With at least one 2-line Alpha keypad (5137AD or 6139) connected to the
Partition 1 keypad terminals on the control, power up the system
temporarily. If you had previously connectedthe AC Im.nsformer to the
controlpanel, you need only plug in the transformer (to 120VAC outlet)to
power up the system.
2.
Enter the programming mode by keying the following on the Alpha
keypa&
Installer code(4112)
+ 8 + O + O.
3. Press $R56.Note
that this is an interactiveprogr amming mode. It is used
to program zone numbers, zone types, partition numbers, and alarm
report codesfor all zonesthat are goingto be used.
w
II
10 Partition
1
I
Enter the first zone number that you wish to
program (or [01[01to exit zone programming).
Normally, you will be starting with zone 10, so
enter "10". Press [*] to continue.
A summary display will appear, showing the
present statusof that zone'sprogramming.
Zn = zone numbeq
ZT = zone @e;
P = partition to which zone is assigned;
RC = report codefor that zone;
In= input type of zone (AW for Aux Wired).
L = Loop (not used for wired expansionzones)
Values
in the summary
display
are the
currently programmed values.
To start programming zone 10, press [*I. A
prompt for ZoneType will appear.
Each zone must be assigned a zone type, which
definesthe way in which the systemrespondsto
faults in that zone. A detailed explanation of
each zone @e
is provided in "Response Type
Definitions" in
Section 18. ZONE RESPONSE
TYPE DEFLA??TIONS.
Enter the desiredzone type,aslisted below.
00= Zone NotUsed
07= 24 Hr Audible
01= Entry/Exit#1
08=24 HrAux
02= Entry fEzit#2
09= Fire
03= Perimeter
10=
Lnteriorw/Delay
04= Interior
Follower
23= NoAlsrm
05. Trouble
D ay/AlarmNight
Response
06=24 Hrsilent
24= SilentBurglary
When the display showsthe zone type you want,
press [*] to continue.
Enter the partition to which a zone is to be
assigned.
Enter "l" or "2".
The default is
partition 1.
Press [*] to continue.