ADEMCO Vista-20 Installation Instructions Manual page 48

Hide thumbs Also See for Vista-20:
Table of Contents

Advertisement

**
***
UseO(Any)for
PartitionNo. (P)
entry.
Or at Disarming,
whichever occurs
earlier.
OHOICW FOR ZONETYPES
00= NotUsed
04=
Interior
F ollower
08=24HrAux
01= Entry~xit#l
05=Trouble D ay/Alarm Night
09=Fire
02=Entry fEsit#2
06=24Hr Silent
10. Interior w/Delay
03=
Perimeter
07=
24 Hr
Audible
24= Silent Burglary
CHOICES FOR SYSTEM OPERATION
20= Arnling3tay
36= **At &U -UP**
42. **System Battery Low
21= Arming-Away
38= Chime
43= Communication Failure
22. Disarming (Code+ OFF)
39= Any Fire Alarm
52= IHasoff
31=
EndofEzit'MU
40=Bypassing
58=
hlYSSS
32=startofEntry!l%ne
41= **AC Power Failure
33=
AnyBurglary A larm
EGE9
Enter (inapplicable)the partition number 1 or 2 (or Ofor any).
Press the [*] key to continue.
m
If a zone list will be used to STOP, or restore,the deviceaction, enter the zone
'n 'St
list number 1,2, or 3 (to be programmedin *8 I mode). If not used, enter O.
Ress the [*] key to continue.
m
If a zone type or system operation will be used to STOP the device action,
fi 'W
enter the appropriatetwo digit code(seethe "ZT'"choiceslisted above). If not,
00
enkr 00. Pressthe [*I key to continue.
=E=lkey'mn"ue
Enter (if applicable)the partition number 1 or 2 (or O for any). Press the [*]
m
This screen again displays a summary of the current device START
programming. Pressthe [*] key to continue.
m
This screen again displays a summary of the current device STOP
programming. Pressthe [*I key to continue.
ml
Enter 1 ifusiug a Powerline Carrier Device(X-10~ if not, enter O.
The display then returns again to the first screen so that the next device
number to be programmed can be entered, or enter [0][0] to end device
S3nming.
progr
Example of
A
lamp is to be turned on via a Powerline Carrier device(X-1O) when any one
Output Devioe
of 3 specificzonesare faulted, or when any 24-hour auxiliary zone is faulted.
Fkogramming
We want to be able to turn off the lamp manually
without affecting the
arming status ofthe system.
To program this, we would do the follo-
In *8O
interactivemode we chooseOutput Device 01 and program the Ac-
tion (A) to be "2" (Close and
stay
closed).The Event we are looking for to
stafi the Device action is a fault, so we will program "2" in (EV). We will
use Zone List 1 for the 3 specific zones,sowe will program "l" in (ZL), (and
we will program these3 zonesin *81's Zone List 1).
The secondconditionfor turning on the indicator is tz-iggetig a 24-hour aux.
zone (Zone Type 08), sowe will program (ZT) as "08.
Next, enter the Partition number (P) in which you want the triggering of a
24hour zone to occu.q enter 1 or 2, or enter Ofor any partition.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents