J.
Zone Number
REa
Zone '&pe (ZT):
Each zone must be assigned to a zone type, which
definesthe way in which the systemrespondsto faults in that zone.
Enter the zone type code (or change it, if necessary).Zone ~es
are
l!
q
Zone
Type "1"
II
20 Partition
1
II
II
20
Repott Code
1st 00 2nd 00
00
II
II
20 Input
Type
RF Trans. RI%
II
II
20 Learn S/N ?
O=NO
I= Yes
O II
listed
below.
00= NotUsed
06= 24 Hr Silent
01= Entry/Exit#1
07= 24 Hr Audible
02= Entry/Exit#2
08=24 HrAux
03= Perimeter
09= Fire Wlverif.
04= InteriorFollower
10= Interiorw/Delay
05= Trouble Day/AlarmNight
.-
20= k-m-stay
21= Arm-Away
22= Disarm
23= No Alarm
Response
24.
SilentBurglary
Default values for zones01 to 08" are:
Zone No.(Zn):
101102!03
I 04105
I 061071081
Zonelvpe Default
109 I 01 I 03
I 03103
I 03 I 03 I 031
Partition Default
1
1
1
1
1
1
1
1
ResponseTime
Default x
1
1
1
1
1
1
1
1
*
"1"
for responsetime = 350 msec.
When the display showsthe zone @pe you want, press [*] to advance
to...
Partition No. (P)
(Default = [1].
Enter'1"
or "2".
Press [*] to advanoe
to...
Report
Code (ItC): The
report codeconsistsof 2 hexadecimaldigits,
eachin turn consistingof 2 numerical digits. For example,for a report
codeof "3C, enter [0][3] for "3"and [1][2] for "C".
Enter the numbers and press[*I to advanceto...
Input
Device (lnh
For the hardwired zones of the VL5W!A-20 (KW),
the auxiliary wired expansion zones on a 4219 or 4229 (AW), the
Input Device types are automatically displayed (Panic, Duress, and
Tamper inputs are not applicable).
For a 5800 system's transmitters, "RF
is initially displayed, but
should be changed to "UIt" (Unsupervised RF, enter 4) for units that
can be carried off-premises (e.g., No. 5801), or to "BR (Button type
RF, enter 5) for small transmitters that cannot be supervised (e.g.,
Nos. 5802, 5802CP, 5803). Refer temporarily to the "5800 Series
Transmitters Table" in
Section
7.
WIRELESS EXPANSION (5800
SYSTEM)
for the specificprocedure required to qearn" a particular
transmitter.
When dl is okay, press [*] to advanceto...
Learning RF Input (L): Applicable
to a 5800-
system (if
used).
This request will be to learn the transmitter serial number. (The
serial numbers can be learned here or via *83 Mode, or entered via
the downloader). We recommend that you use *83 mode if you are
only changing a wirelesstransmitter, and wish to maintain the other
zone parameters.