ADEMCO Vista-20 Installation Instructions Manual page 30

Hide thumbs Also See for Vista-20:
Table of Contents

Advertisement

II
10 ReportCode
1st 03 2nd 12
3C
II
Typicalsummary display
The report codeco~ists of 2 hexadecimaldigits,
eachin hum consistingof 2 numerical digits. For
example, for a report code of "3C", enter [0][3]
for "3" and [1][2] for "C". Refer to
SYSTEM
COMMUNICATION
section for
complete
information on report codes, i f necessary.
Enter the report code and then press [*I to
continue.
A summary display will appear, showing the
data for the zone that was just programmed.
Note that AW indicatesan auxiliary wired (zone
expansionmodule) zone.
If it is programmed satisfactorily, press [*I to
display the next prompt.
For all zone lypes, the next request is to enter
Alpha descriptorsfor the zones. The entry may
be done now (enter 1) or maybe done at a later
time using *82 interactive mode (enter O). We
recommendthat the entry of Alpha descriptors
be done later using *82 interactivemenu mode.
See Section 15.
ALPHA
DESCRIPTION
PROGRAMMING
for specitic procedure.
'lpretio.slY
If "O" (No) was entered above, the system will
display a prompt for entry of the next wired
expansion zone number. Proceed with the
programming for the next zone, as indicated
When you have programmed all the wired
expansion
zones
satisfactorily,
exit
*56
interactivemode at the Enter Zn Nu.m. prompt
by pressing [0] [0]*.
Themexit the programming g mode by keying ~.
Proceedto the check-outprocedurethat follows.
-30-