This section provides instructions for installing
5800 series wireless receivers and
transmitters and includes a procedurefor programming wirelesszones.
General Information
In addition to its basic wired zones, the control supports up to 24 wireless
zones using an appropriate 5881 (5882 in Canada) type RF receiver. The
actual number of zones supported also depends on whether you are using a
wired zone expander module.
For exampk:
If you are using only four of the wired expansion loops, a
5881H (5882H in Canada) RF Receivercould add 20 RF zones to the system,
using any zone numbers in the range of 18-83, for a combined total of 24
wired and wirelessexpansionzones.
However, if you are not using wired zone expansion, the 58811V5882H RF
receiver could add 24 wireless zones to the system, using any zone numbers
in the range of 10-83.
The receiver can detect signals from wirelesstransmitters within a nominal
range of 200 feet.
Receiver Supervision
The receiver is supervised, and a trouble report will be generated. CHECK
and zone 09 will also be displayed.
a) If communicationbetweenthe panel and the receiveris interrupted.
or
b) If no valid RF signals from at least one
supervised
wirelesstransmitter
are receivedwithin 12 hours.
House Identifkation
If you are using a 5827 or 5827BD Wireless Keypad with the system, you
must program a House ID Code (O1-31) in field *24 to establish proper
communication,and the keypad must be setto the sameID.
DIP switch setting information for a 5827 is given later in this section. The
5827BD is keypad programmable.