OptiOnS
Defined
The following will help you understand the programming of OUTPUT
DEVICES when using *8O and *81 modes. The options used to start and
stop thesedevicesare describedbelow,followedby the actual screenprompts
and availableentries.
The letter(s) in parenthesesafter each function describedbelow, such as (A)
tier
ACTION, are those that appear in the various summary displays of
programmeddata during programming.
ACTION (A)
The "ACTION"
of the deviceis how the devicewill respond
when it is activated by the "START
programming. You
may want the deviceto activate momentarily, to pulse on
and off continuously, or to remain activated until some
other event occurs to stop it.
There are four different
choices of actions:
. ACTIVATE for 2 SECONDS and then reset.
c ACTIVATE and REMAIN ACTIVATED until stoppedby
someother event.
. PULSE ON and OFF until stoppedby someother event.
Q NOT USED when the deviceis not used.
START (S27') The
"START" programming determines when and under
what conditionsthe devicewill be activated. The following
START options are available:
A)
1. EVENT
(EV) is the condition (Alarm, Fault, Trouble) that
must occurto a zone or group of zones (zone list) in order to
activate the device. These conditions apply
only
when a
zone list is used. The different choicesfor "EVENT" are
listed below and in the "Programming Output Relays &
Powerline Carrier devices"sectionthat follows.
Q ALARM
Relay action begins upon any alarm in
an assignedzone in the zone list.
. FAULT
Relay actionbegins upon any opening or
short in an assigned zone in the zone
list.
TROUBLE
Relay action begins upon any trouble
conditionin an assignedzone in the zone
list.
. NOT USED
Relay action is not dependent upon one
of the aboveevents.
2. ZONE
LIST
(ZL)
is a group of zones to which the
"EVENT" applies in order to activate a particular device.
Note that there are a total of 3 zone lists that can be
programmed in field *81 mode; when the selectedEVENT
(Alarm, Fault or Trouble) occurs in any zone in the
selected"Start" ZONE LIST (1, 2, or 3), activation of the
selected devicewill START.
B)
1. ZONE TYPWSYSTEM
OPERATION
(ZT).
If a System
Operation,
such as "DISARMING"
or "ANY
FIRE
AIARM," is to activate the device, the appropriate choice
would also be entered under the "ZONE TYPE" option.
"ZONE
TYPE"
is
used
independently
of
the
"EVENWZONE LIST" combination.
If a specific"ZONE TYPE"
is
chosen, any zone of that re-
sponsetype going into alarm, trouble, or fault will causethe
device to activate as selected in "ACTION." If the same
"ZONE TYPE" is also chosen for the STOP programming,
any zone of that type that restores will de-activate the
device.