ADEMCO Vista-20 Installation Instructions Manual page 91

Hide thumbs Also See for Vista-20:
Table of Contents

Advertisement

TRANSMIT NOW
I
Typical
SummsryDisplay
A.cew
II
Program Alpha?
O=NO
I= Yes
O
II
If "yes"is selectedin responseto the previous prompt, the "Transmit
NoN display will appear.
Open and close(or closeand open),or pressand releasethe particular
input to the transmitter twice.Atter the fist time, a single short beep
will occur.After the secondtime, two short beepswill mean that the
control has acceptedthat transmitter into the system. The display
will revert to the summary line, with the accepted input (loop)
number under the "L in the display. Because of the character-
istics of the receiver, allow about 8 seconds between first and
second transmissions
from
button
(BR)
units
(e.g., 5802,
5802CP, 5808). If a long beep occurs,it means that the particular
transmitter input has previously been learned in the system. Mark
the zone number on the transmitter.
After a lmnsmitter has been Ieamed, a summary of the programmed
values for the selectedzone wiU be displayed.
If all is okay, press [*I.
Custom Alpha Editing
For all zone types, the next request is to
enter Alpha descriptors for the zones. The entry may be done now
(enter 1), or maybe done at a later time via *82 mode (enter O).
See
Section
15. ALPHA DESCRIPTION
PROGRAMMING
for
procedure.
When all entries to be made for the zoneat this time are complete, the
next zone number
can be entered for programming,
or zone
programming can be ended by entering [0][0] as the next "zone
number".
Notes:
1.
2.
3.
ZiEF=l
4"
20 Delete Zone?
l= Yes O=NO
II
5.
When using a
5801, the Input (Loop) "4" button should alwaysbe
used and learned by the systemfirst.
In @d
*56, at the summary line for each zone, the entered values
can be chsched.
If it is desired to change anything, press [#] to
moveto the previous entry. Press [#] a number of times to move to
earlier entries. Press [*] to moveto later entries again.
Zone
entries can be reviewed
by pressing [#][5][6]. Changes cannot
be made here, so this is safer for review. Enter the first zone
number to be viewed and press [#]. To view each zone, press [#]
and the zone number will advanceto the next programmed
zone.
When the end of the list is reached, press [0][0] to exit. This
method of exiting may alsobe done at any time during the review.
To either temporarily or permanently
remove a zone j%om the
system, go
into
programming mode and press [*][5][6]. Enter the
zone number and press [*]. At the "ZoneType" prompt, enter [0][01
and [*]. This sets the type of the zone to mot Used". The next
prompt will be "Delete Zone?"."Yes"will permanently remove the
zone from the system,while "No" will disableit but retain all data
exceptthe original zone type. You can then go back to this zone
later and put back an activeZoneType to re-enableit.
An ID code thut has been learned for a 5800 system will not be
deleted
if the
zone is disabled
as
described above.
If only the
physical transmitter is to be removed or changed (i.e., its ID code
deleted, as when replacing a unit that has a non-removable
battery), it can be done in j?kld *56 or -3.
In the programming
mode, press [*][5][6], enter the zone number, and press [*I
multiple times until the cursor is under the Learned RF Input (L)
position. This is the specificinput (loop) or button on tie tr=mit-
ter that has been learned for that zone. If a [0] is entered at this
point, a prompt "Delete S/N?' will appear. If "Yes"is entered,this
sptic
ID codewill be deletedfrom the system.