ADEMCO Vista-20 Installation Instructions Manual page 49

Hide thumbs Also See for Vista-20:
Table of Contents

Advertisement

ZoneList Displays4
b
To
stop
the Device action and turn off the lamp, we do not want to use a
restore of eny zone, so a "O will be programmed for the
Restore of
Zone List
(zL). We will use a manual
entry of User Code+ [#] + [8] + Device #
to
turn off. Therefore,we do not need to program a STOP event.
Press [*I to continue.
The systemwill display a summary screenfor the START progr amming for
device01. Ress [*I to continue.
The system will display a summary screen for the STOP progr emming for
device01. Press[*I to continue.
The systemwill displaythe "2UO? prompt. Enter 1 for yes.
The
Enter
Device No. prompt for the next zone will be displayed.
Press 00 and then [*I to etit the *8O mode.
Now use %1 Zone List modeto program the 3 specificzonesin Zone List 1.
Press
*81.
(Zone Lists for Output Devices]. This interactive mode is
applicableonly if you have programmed *O mode.
Referto the Programming Form worksheetfor *81 Mode.
Upon keying *81, this screenwill appear. Enter the Zone List Number 01,02,
or 03 to program (or 00 to end these enties). Ress the [*] key to advance.
In the followingdisplays,zone list 01 has been selected for programming.
Enter each zone number to add to the zone list by first entering the zone
number, then the [*I key (example,01*, 02*, 03*). ~er
~ zonesdesired ~
entered,press00 to advance.
To deletethe zonelist, enter 1 (Yes). AU zones in the zone list will be deleted
automatically.and progr amming will return to the fist screen.
To savethe zonelist, enter O (No) to advance.
To savethe entire zone list, enter O (No) md Programming will return to the
first screen.
To deletea zoneor zonesin a zone list enter 1 Wes) to advace.
Enter each zone to be deletedfrom the@
followedby the [*I key. After ~
zonesto be deletedare entered, enter 00 to return to the first screenso that
enotherlist canbe programmed,if desired.
Notes:
"
Any list may include any or all of the system'szone numbers.
.
A zonelist canbe assignedto more than one output relay.
If you only want to review what has been programmed previously
enter
[#][8][1]. The review can be advancedby using the [*I key. when fishe~
enter [0][01* to quit. No programmed values can be changedin this mode.
When programming
in *8O and *81 titiractive
~odes is completed,
exit the programming mode by keying w.
Unplug the AC transformer.