Specifkations
VISTA-20
SECURITY
CONTROL
4127
REMOTE KEYPAD
4137AD & 5137AD
REMOTE KEYPADS
1. Physical
12-1/2 W
X
141/2°
H
X 3"
D (318mm
X
368mm
X
76mm)
2. Electrical:
VOLTAGE INPUT: 16.5VAC fromplug-in 25VA transformer, A demcoNo.
132UI'F2 (in U.S.A)
RECHARGEABLE BACK-UP BATTERY: 12VDC, 4AH (Gel type).
ChargingVoltage: 13.8VDC.
ALARM SOUNDER: 12V, 2.0 Amp output can drive 12V BELLS or can
driveone or two 702 (series connected) self-contained 20-watt sirens. Do
not connecttwo 702s in parallel.
AUXILIARY POWER OUTPUT: 12VDC, 600mA max. Interruptsfor 4
wiresmokedetectorreset.
Note: For VL instaUations, Alarm Sounder plus Au&my
Power currents
should not exceed 700rnA total.
STANDBY TIME: (see
Table in POWERING THE SYSTEM section)
FUSE:
Battery (3A) No. 90-12
3. Communication:
FORMATS SUPPORTED:
Ademco Express,
10 charactershec,DTMF (TouchTone)Data Tones, 1400/2300HzAC~
1400HZKIssoFF.
Ademco Contact ID Reporting,
10 charactershec.,DTMF (TouchTone)Data Tones, 1400/2300HzAC~
1400HZKIssoFF.
Ademco Low Speed, 10 pulses/see,1900Hz Data Tone,
1400Hz ACIVKISSOFF.
R.adionics/SESCOA&20 pulseslsec,1800Hz
Data Tone, 2300Hz
ACKKISSOFF. Cm
report
O-9, B-F
Line Seize:
Double Pole
Ringer Equivalence: 0.7B
FCC Registration No.: AC 398U-68192AL-E
4. Maximum
Zone Resistance:
Zones1-8= 300 ohms excludingEOLR
1. Physic*
5-5/8" W X 4-11/16' H X 7/8" D
(143mm X l19mm X 22xum)
2. Electrical
Voltage Input: 12VDC, Cument Drain: 20mA
3. Interfkce Wirin~
To control panel's keypad connectionpoints.
RED:
12VDC input (+) aux pwr
GREEN:
Data Out to Control
YELLOW
Data In from Control
BIACIQ
Ground
1. Physicak
8-2/5" W X 43/4' H X 1-IJ1O"D (213mm X 121mm X 28mm)
2. Electrical:
Voltage Inputi
12VDC,
Current Drain
60mA (4137AD)
9ormM5137AD)
3.
Interface Wiring:
RED: 12VDC input (+) aux pwr
BLUE: 18VDC input horn optionalNo 1350 or 1360 PowerPack
(not usableforUL installations)
GREEN: Data Out to Control
YELLOW
Data In fkomControl
BLACK
Ground(–) connection fromoptionalNo. 1350/1360 PowerPack.
-I oa