Alarm Bell Timeout; Zone Type 01 Entry Delay; Audible Exit Warning; Power Up In Previous Satte - ADEMCO Vista-20 Installation Instructions Manual

Hide thumbs Also See for Vista-20:
Table of Contents

Advertisement

DIALER
PROGRAMMING
(~)
*34
*35
*36
*37
*36
ALARM BELL TIMEOUT
n
This field determineswhether the external sounder will shut off after
time allotted,or continueuntil manually turned off. Enter as follows
O= No timeout 1 = 4 rnin (default); 2 = 8 ti,
3 = 12 min.
Alarm bell timeout must be set for a minimum
of 4 min ("1=)
for UL installations.
ZONE TYPE
01 ENTRY DELAY
Partition1
Partition2
Systemwill wait the time allotted before sounding alarm upon
entering. May be selected individually for each Partition.
o=
O seconds 2 =30 seconds 4 =60 seconds
1 =20 seconds 3 =45 seconds
5 =90 seconds
Default is 2 (30 seconds).Entry delay must be set for a maximum
of 20 seconds in UL installations.
Zone~
02 Entry Delay= Zone Type 01 Entry Delay+ 30 seconds.
(EXIT delays= Zone type 01 En@
delay plus 40 seconds).
AUDIBLE
EXIT WARNING
Partition1
Psrtition2
If enabled,this field provides exit warning sound when armed AWAY
it canbe selected for either or both Partitions.
Warning sound consistsof slow continuous beepsuntil last 5 seconds,
when it changes to fast beeps. The warning sound will end at the
termination of Exit time.
O= no; 1 = yes. Default is 1.
CONFIRMATION
OF ARMING
DING
Part%1
%rt?n2
Enter 1 (in either or both Partitions) to enable l/2 second external
alarm sounding"ding" when closingreport goesin, or at the end of exit
delay. O disablesthe "iii@' (default).
POWER UP IN PREVIOUS
STATE
•1
Enter 1 for Yes (default) if, upon power-up, you want the system to
assumethe systemstatus prior to power down. Enter O if you want the
systemto alwayspowerup in a disarmed state.
When the systempowersup armed, an alarm will occur 1 minute after
arming if a zone is faulted. Must be *1" for UL installations.
Note that if the previous state was armed AWAY or STAY, the system
will not respondto sensorchangesfor 1 minute, which allowstime for
sensorssuchas PIRs to stabilize.
Enter
up-
to- the
number
of
digits
shown.
Do not fill
unused spaces.
Enter O-9,
# + 11 for '*'
# + 12 for%'
# + 13 for a pause
(2.5 sees)
PABX ACCESS CODE (See
Box at Left)
Ill
Enter up to 4 digits if PABX is needed to accessan outside line. If
fewer than 4 digits are needed to be entered, exit by pressing * and
next field number (e.g.,41). To clear enlries horn field, press ZO*.
PRIMARY PHONE No. (See
Box at Left)
I
1111111111!
Enter up to 12 digits. If fewer than 12 digits entered, exit by pressing
*ad
na
field n~ber
(e.g., 4 2).
TO
clear entries from field, press
%1*.
Note: Back-up reporting (8 calls are made to the secondary phone
number if no kiss-off is received after 8 attempts to the primary
number) is automaticonly if there is a second-
phone number (field
*42).
SECONDARY PHONE No. (See
Box at Left)
11111111111
Enter up to 12 digits. If fewer than 12 digits entered, exit by pressing
* and next field number (e.g., 43). To clear entries from field, press
*42*. SeeNote above,also.