ADEMCO Vista-20 Installation Instructions Manual page 81

Hide thumbs Also See for Vista-20:
Table of Contents

Advertisement

See TO PROGRAM SYSTEM STATUS AND RESTORE REPORT CODES
explanation on
previous page for fields *66-*76, and *89.
Press -
Press *7
Press MM
Press *7O
Press *71
Ress *72
Press *73
Press *74
Press *75
-S
*76
Press *S9
Press @O
o=
Part>n1
Part'n 2
ARM AWAY/STAY REPORT
CODE
0
no
AWAY WAY
AWAY W'AY
This option allows for independent programming of AWAY and
STAY reports for eachpartition. 2nd digit of Reportis User No., if
expandedor 4+2 reporting is selected.
RF XMTRw LOW BA'ITERY
REPORT
CODE
o I
This
is sent in the event that a wireless lmusmitter low battery
conditionexists.
CANCEL REPORT
CODE
o I
This is sent upon disarming of the system after an alarm
conditionwas reported.
A1.ARM RESTORE
REPORT
CODE, 1st DIGIT
n
This is sent when the zone that caused an alarm is restoredto its
non-faulted condition. 2nd digit is automatically sent as the 2nd
digit of the zone alarm report code programmed in field *56, if
expandedor 4+2 reporting is selected.
TROUBLE
RESTORE
REPORT
CODE
n I
This is sent when a trouble in a zone is restored.
BYPASS RESTORE
REPORT
CODE
m I
This is sent when a zone that has been bypassedis un-bypassed.
AC RESTORE
REPORT
CODE
n I
This is sent when AC power has been restored after an AC power
outage. Reports with Partition 1 Subscriber No.
LOW BAT RESTORE REPORT CODE
n I
This
is sent when a system low battery condition is restored to
normal.
RF XMTR.
LOW BA'IY'ERY RESTORE CODE
n I
This is
sent when a transmitter that previously sent in a low
battery messagehas sent a messageindicating it no longer has a
low battqy condition.
TEST RESTORE
REPORT
CODE
m
This is sent when the test modeis exited. Reportswith Partition
1 SubscriberNo.
EVENT LOG 8(MoFULL REPORT
CODE
n I
If an Event Logging selection is made in field *O, a messagecan
be sentto the central stationreceiverwhen the logis 80% fid.1.
Notcx Aside horn the selection made by the installerin field *O,
all log control and readout is accomplishedvia the Downloader.
EVENT LOGGING
None 1 = Alarm/Alarm Restore 2 = Trouble/Trouble Restore
4 =
Byp~s/Bypass Restore;
8 =
Open/Close. Default is "3".
"
ExczmpZe:
To select"Alarm/Alarm Restore",and "Open/Close",enter 9
(1+ 8); to selectall, enter #15.
Note: Systemmessagesare loggedwhen non-zero selections are made.
See Fields W9 and SO in
Section 19. DATA FIELD DESCRIPTIONS
for a more detailed descriptionof Event Logging.
-81-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents