ADEMCO Vista-20 Installation Instructions Manual page 46

Hide thumbs Also See for Vista-20:
Table of Contents

Advertisement

2
STOP (STP):
A)
1.
B).
1.
2.
If a "SYSTEM OPERATION'-is
chosen (e.g., End of Exit
Time), that operation will cause the device to activate as
selectedin "ACTION."
The different choices for "ZONE
TYPE"
and
"SYSTEM
OPERATION"
are listed
in
"Programming g Output Relays & Powerline Carrier devices"
later in this section,and in the Progmmming Form.
PARTITION
No.
(P).
The
device's "Start"
ZONE
TYPE/SYSTEM
OPERATION
may be limited to sn occur-
renceon Partition 1, Partition 2, or any partition (A).
The "STOP
programming determines when and under
what conditions the device will be de-activated. The
following options are available:
RJE3TORE
ZONE
LIST (ZL). If a "ZONE LIST
is used
as the "Stop" event, the device will de-activate when all
the zones in that list restore horn a previous fault, trouble,
or al-
condition. This will occur regardless of what is
programmed
to "START"
the
device; therefore,
a
"RESTORE ZONE LIST'
would normally only be used
when a "ZONE LIST is used to start the device.
ZONE TYPWSYSTEM
OPEBATION
(ZT).
Instead of
using a "RESTORE ZONE LIST,
a specific zone (response)
type or system operation action can be selected to de-
activatethe device.
If a specific "ZONE TYPE" is chosen,any zone of that
responsetype that restoresfiwm a previous alarm, trouble,
or fault conditionwill causethe deviceto de-activate.
If a "SYSTEM OPERATION
is chosen,that operation will
causethe device to de-activate. The ~erent
choicesfor
"ZONE TYPE" and "SYSTEM OPERATION
are listed in
"Programming Relays & Powerline Carrier devices"later
in this section,and in the Programming g Form.
PARTITION
No.
(P).
The
device's "Stop" Zone
~e/System
Operation maybe limited to an occurrence on
Partition 1, Partition 2, or any partition.
46-