Check-Out Procedure For Wired Expansion Zones - ADEMCO Vista-20 Installation Instructions Manual

Hide thumbs Also See for Vista-20:
Table of Contents

Advertisement

check-out
Procedure For Wmd
EX@iWSiOQ
Zcmes
-
After you have completedinstallation of all devices, all expansion zones in
euch
ptition
of the security systemshouldbe checkedas follows:
1.
2.
3.
4.
5.
Make certain that all devices and sensors connected to the wired
expansion zones are not in a faulted state. Doors and windows with
contactsshould be closed, PIRs should be covered (use a cloth to mask
them temporarily if necessary).
With all zones intact (including hard-wired zones), the Alpha keypad
connected to the systemshould display:
~~
If the followingis displayed,
m
press the [*] key to display the faulted zone(s). Restore any faulted
zone(s) as necessary(also make sure that you have connecteda 1000 ohm
EOL resistor acrossthe terminals of unused expansion zones on the 4219
or 4229 module).
When the READY TO ARM messageis displayed, you can proceedto the
next step.
Fault and restore every contact or sensor in each expansion zone
individually to ensure that it is being monitored by the system. Each time
a zone is faulted, the keypad should display the number of the faulted zone
(as programmed by you just previously in *56 mode). When each zone is
restore~ the READY TO ARM messageshould appear again.
If some wired expansion zones have been assigned to partition 1 and
others to partition 2, you will need to observe the keypad in the
appropriate partition as eachzone in that partition is faulted and restored.
When you get the proper displays on the keypad(s), the tied
expansion
zonesin the systemare functioning properly.
Unplug the AC transformer.
+1-