Using The Transmitter Sniffer Mode; Deleting A Transmitter Serial Number From A Zone In 56 Mode - ADEMCO Vista-20 Installation Instructions Manual

Hide thumbs Also See for Vista-20:
Table of Contents

Advertisement

Using The Tmnsmitter Sniffer Mode
1. Enter Installer code (4112)+ # + 3. This initiates a procedure that will
providea checkthat all transmitters have beenproperly programmed.
2. The keypad wilI display all zone numbers of wireless units programmed
into the system.Fault eachtianemitter in tumq causingeach one to send a
signal, rather
than
let each transmitter
send
an automatic
supervisory signal. An automatic supervisory signal that is receivedin
this modewill be misinterpreted as a low battery signal.*
As the system receives a signal fkom each of the transmitters, the zone
number of that transmitter
will disappear
from the display. The
transmittersmay be checkedupon installation, or in an installed system.
Note: A transmitter not "learned"will not turn off its zone number.
3. When all transmitters
have been checked, exit the sniffer mode
immediatelyby keying Installer code (4112)+ OFF.
* If oneor morelowbattery messages d oappearafterexiting the sniffermode, doone
ofthefd.lowing
A
Fault eachzonethat is showing a lowbattery,then entera disarmsequence
(Code + OFF) to clear the lowbatterydisplay, o r..
B. Enterandexitthe programming mode.This will clearany lowbatterysignals
&ommemory.
~~p
To Either T
ermaneatly Remove A Zone From The System.
1. Enter the programming mode and press [*1[51[61.
2. Enter the zone number and press[*I. A summary display will appear.
3. Ress [*] again.
m
'ess[*]timntiue
4. The "Zone Type" prompt will appear. Enter
[01[01. T his setsthe zone type to "Not Used".
-
"le'thezOne"
5. The next prompt will ask whether you want
'Yes" vnll permanently remove the zone fkom
the system,while a "No" will disable it but re-
tain all data exceptthe original zone @pe. You can then go back to this zone
later and put back an activeZone Type to re-enable it.
A serial number that has been learned for a 5800 system will not be
deleted if the zone is temporarily
disabled by answering
'Non to the
prompt above.
If only the physical transmitter is to be removed or changed (i.e., its sefia.1
number deleted,as when replacing a unit that has a non-removable battery),
it can be done in *56 Mode, but we recommend using the *83 mode (in a
later section of this manual).
Deleting a Transmdt " erSerial Nmnber Froma~in
x56 Mode
Abbreviated
1.
Procedure:
2.
3.
4.
5.
6.
~o~~
programming mode, press [*1[5][61to enter Zone Programming
"
Then.enter the zone number, and press [*I mpeate~y ~fl
the cursor iS
under the %mmed
RF Input (L)" position. ~S
is the spefic mPut
(loop)or button on the transmitter that has been learned for that zone.
En~
a [O]at this point, then press [*I.
A prompt "Delete S/N?" will appear.
Enter 'Yes" to deletethe existingserial number from the system.
Note that the other programmed values for that zone will not be deleted.
This will allowyou to r~instate a new transmi tter in its place.
A displayfor the next zone number will appear.To exit, enter "00 *"
Press*9 to exit the programming mode.
-39-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents