Setting the AE Bus Timeout

SUPPLY → AE BUS
To set your AE Bus timeout time:
1. Press SUPPLY → AEBUS.
2. Rotate the MODIFY knob to adjust the AE Bus time out value (in 10 ms
increments).
3. Press ENTER to accept and exit.
Note: We recommend you keep this value as small as possible to speed up error
recovery due to noise.

Setting the Supply Parameters

SUPPLY → DEFAULTS
To set all your supply parameters to the defaults and then store them in non-
volatile memory:
1. Press SUPPLY → DEFAULTS.
2. Rotate the MODIFY knob to display Yes or No.
3. Press ENTER to accept and exit.
4. Cycle power on the supply for the defaults to take effect.

Setting the Panel Mode

SUPPLY → PANEL
Use this option to select between a remote and local control panel, lock the control
panel, set the lock code, or set the encoder rate for the knob clicks.

SELECTING REMOTE OR LOCAL MODE

SUPPLY → PANEL→ SELECT
To switch between the remote active panel and the local active panel:
1. Press SUPPLY → PANEL → SELECT.
2. Rotate the MODIFY knob to display Yes or No, depending on whether or not you
want to switch to a remote/local active panel.
3. Press ENTER to accept and exit.
4. Wait several seconds for verification of switch before using the other control
panel.
4-28
I/O Communication and Control
5702156-E