Ae Bus (Host) Communications; Ae Bus Protocol; Baud Rate Settings - Advanced Energy Pinnacle User Manual

20 kw (325-650 vdc) devicenet, ae bus, mdxl user, terminal block output
Table of Contents

Advertisement

Pinnacle™ 20 kW
Table 4-16. Baud Rate Settings
Baud Rate
RS-232
1200
4800
9600
19,200

AE BUS (HOST) COMMUNICATIONS

The following sections describe the AE Bus (Host) port communications.

AE Bus Protocol

The AE Bus protocol uses pure binary data (nothing is coded in ASCII) and is
designed to facilitate direct communications between a host computer and the
Pinnacle.
The AE Bus message packet combines a set quantity of bits and bytes in such a way
that groups of information can be sent over communications lines at one time. Five
types of information (fields) make up communications message packets (see Figure 4-
16):
• Header (address and the length of Data field)
• Command Number (the commands are listed in Table 4-18 on page 4-63)
• Optional Length byte
• Data
• Checksum
5702156-E
Baud Rate
RS-485/422
9600
19,200
38,400
57,600
I/O Communication and Control
BR0
BR1
up
up
up
down
down
up
down
down
4-55

Hide quick links: