Pinnacle™ 20 kW
Table 5-3. Contactor Interlock Pin Descriptions
Pin
Return
Pin
5
8
6
8
7
8
8
n/a
9
8
Connecting for DeviceNet™ Control
If you have a DeviceNet interface, please reference the DeviceNet section in chapter 4
of this manual for instructions on connecting it.
Note: To reduce EMI interference, we recommend using shielded cable to connect to
the serial port.
5702156-E
Pin Name
Remote Arc Shutdown
(Side B)
Remote Arc Shutdown
(Side A)
Arc Detect (Side A)
n/a
Arc Detect (Side B)
Installation
Signal
Description
Type
Input
To enable a remote arc
shutdown (Pin 5 for side B;
Pin 6 for side A), apply 15 V
Input
to the pin to signal a shutdown
of output power for the
Pinnacle unit. The unit
remains in the arc routine until
the pin is brought low again.
Note: This sequence does not
turn OFF the unit
because the unit thinks
that an arc exists and
enters the arc routine.
The unit does not come
back ON because its
logic board detects
current on the output
connection.
Output
When high, this pin signals
(0 to 15 V)
that the output voltage of the
Pinnacle unit is below the arc
trip level set.
n/a
Common return pin and
reference for Pins 5, 6, 7, and
9
Output
When high, this pin signals
(0 to 15 V)
that the output voltage of the
Pinnacle unit is below the arc
trip level set.
5-9