Table 4-6. Network Status LED (Continued)
If the LED is
Flashing Amber
Amber
For information about Module Status LED indications during power-up, refer to
Section 8.2.4 of the DeviceNet Specification (revision 2.0).

PASSIVE DISPLAY PANEL

The passive front panel and remote passive panel let you monitor power, current, or
voltage; receive error codes; and review several other conditions shown by the LEDs.
Note: The master/slave functions listed in this section apply only to Pinnacle supplies
with a master/slave Host card installed.

Display

At any time while the Pinnacle supply is operating, you can press the DISPLAY
buttons to the left of the four-digit display to find the number of kilowatts (or watts),
volts, or amps being delivered.
This display also shows error codes when a fault or software error has occurred. For a
detailed explanation of these codes and other troubleshooting materials, see the
"Troubleshooting" chapter.
4-12
the state indicated is
Connection Time-out,
Critical Link Failure
Critical Link Failure
I/O Communication and Control
which means that
one or more I/O
connections are in the
timed-out state.
communication has
failed; that is, the unit has
detected an error that has
made it incapable of
communicating on the
network.
Note: If you have a dual
Pinnacle unit, the
causes of this
failure may be: 1)
the two DeviceNet
cards are not set to
the same Data Rate
as the network; or
2) the two
DeviceNet cards
have the same
Node Address.