OPERATING OVERVIEW

The following list represents a general description of how to operate a Pinnacle unit.
You will want to adapt this list to your Pinnacle configuration and your application,
environment, and requirements.
Note: If an error code (that is, an "E xx" code) appears on the front panel or on the
Pinnacle Remote Active Panel, refer to the "Troubleshooting" chapter for an
explanation and troubleshooting suggestions.
1. Turn on the Pinnacle unit.
4 Verify your unit's LEDs. If you are using a passive panel, verify that the
POWER ON and INTERLOCK LEDs light. If the INTERLOCK LED does not
light, an error code should appear (see the "Troubleshooting" chapter for more
information).
4 If you are using an active front panel or a Pinnacle Remote Panel, verify that
the display screen displays two messages in sequence: "Advanced Energy, Fort
Collins, Colorado" and then "Power Up Sequence, Please Wait." In addition,
verify that an LED lights to show the control setting and another lights to show
the regulation setting. Finally, verify that the OFF LED lights.
Note: The unit defaults to the previously selected control and regulation settings.
If the unit had been in LOCAL mode with a Pinnacle Remote Panel but
the Remote Panel is removed, the unit will boot up in Host control mode.
If there is no Host card, the unit will boot up in User control mode. An
active DeviceNet card will act as a Host card, but if the DeviceNet card is
not active the unit will boot up in User control mode.
Note: If the display screen shows no message and/or if no control or regulation
LEDs light, ensure that the unit is properly installed and is receiving AC
input power.
2. Check non-lighted LEDs and the display panel. If you are using the passive panel,
verify that the BUS FAULT and OVERTEMP LEDs are not lit. If either or both
is lit, power down the Pinnacle unit, clear the fault, and return to Step 1. (Refer to
the "Troubleshooting" chapter for error code explanations and troubleshooting
suggestions.)
4 If you are using an active front panel or the Pinnacle Remote Panel, verify that
the "output display screen" information shows on the display screen (see the
"Active Front Panel/Pinnacle Remote Panel" section of Chapter 4 for details).
If the display screen shows an error code and message, note the error code
number and refer to the "Troubleshooting" chapter.
5702156-E
Pinnacle™ 20 kW
Operation
Chapter
Chapter
6
6-1