Leds - Advanced Energy Pinnacle User Manual

20 kw (325-650 vdc) devicenet, ae bus, mdxl user, terminal block output
Table of Contents

Advertisement

Pinnacle™ 20 kW
When only a Passive Front Panel (PFP) is available, the Pinnacle unit will display 4
character strings on start up to identify personality cards installed in the unit. A code
will flash once for each card installed. The following table describes the strings:
Table 4-7. Passive Display Panel Codes
PFP Display
String
H----
H-01
H-03
H-04
H-05
H-18
H-22
H-30

LEDs

Table 4-8. Display Panel LEDs
POWER ON
OUTPUT
SETPOINT
5702156-E
Personality Card
No Cards
Dual User Card
PROFIBUS Card
Host Protocol Translator Card
Single User Card
AE Bus Card
Master/Slave Card
DeviceNet
Lights green when input power is on
Lights green if output power is on
Lights green if the Pinnacle supply is
operating within setpoint:
• For a stand-alone unit, accuracy is within
0.4% of full scale or 2% of setpoint,
whichever is greater.
• For master/slave systems, setpoint range
is 3.125% of the full scale of the system.
Note: The master of a master/slave
system is also constrained by the
stand-alone out-of-setpoint limit.
This limit (0.4% of full scale or
2.0% of setpoint) only applies to
the output of the master in the
system.
I/O Communication and Control
4-13