Setting Ripple Level - Advanced Energy Pinnacle User Manual

20 kw (325-650 vdc) devicenet, ae bus, mdxl user, terminal block output
Table of Contents

Advertisement

®
Advanced Energy
1. After you have entered a value from 1 through 8 at the # OF STEPS screen (see
steps 1 through 2 above), you should be looking at a screen that requests a RAMP
TIMER value.
2. Rotate the MODIFY knob to select a value between 0.05 s to 600 s (in 0.01 s
increments).
3. Press ENTER; the display progresses to a screen requesting a SETPOINT value.
4. Use the REGULATION key to toggle between power, current and voltage. Use
the MODIFY knob to select a value between 0 and the full rated output of the
supply.
5. Press ENTER; the display progresses to a screen requesting a RUN TIMER value.
6. Rotate the MODIFY knob to select a value between 0.00 s to 600 s (in 0.01 s
increments).
Note: If your unit has the 100 ms ramp feature, the range is 0 s to 6000.0 s.
7. If you are turning the MODIFY knob slowly, press the appropriate soft key to
indicate how quickly you want the display to increment the value (x10 or x1).
Note: If you turn the MODIFY knob quickly, the counts per click setting takes
8. Press ENTER; if you have indicated that your recipe contains more than one step,
the display returns to the RAMP TIMER screen so that you can enter recipe values
for the next step.
9. Repeat Steps 2 through 7 as needed.
Note: If you assign 0 run time for the final recipe step, the unit will switch to
continuous output when it reaches setpoint for this step. In this situation, to turn
off output, you must send an off command (using the OFF button or the
appropriate User port signal or serial port command) or you must have already
programmed a joules setpoint.
Note: The setpoint source must be set to internal to run a recipe. See "Setting the
Program Source" on page 4-29 for more information.

Setting Ripple Level

PROCESS → CONTROL → RIPPLE
This function lets you set the output ripple to either a low amplitude ripple (less than
2%
) or a high amplitude ripple (4% to 5%
RMS
To set the RIPPLE mode:
1. Press PROCESS → CONTROL → RIPPLE
2. Rotate the MODIFY knob to select "low" or "high."
3. Press ENTER to accept and exit.
4-42
effect.
I/O Communication and Control
).
RMS
5702156-E