Advanced Energy
Rear Panel LEDs
The rear panel of the Pinnacle unit features two bi-color LEDs (see Figure 4-3). One is
labeled MOD and indicates module status. The other is labeled NET and indicates
network status.
MODULE STATUS LED
The MOD bi-color (amber/green) LED provides device status. It indicates whether
the device has power and is operating properly. The following table shows the LED's
various states and their meanings.
Table 4-5. MOD Status LED
If the LED is
Green (steady)
Flashing Green
Amber
Flashing Amber/
Green
For information on LED flash rates, refer to section 8.2.8 of the DeviceNet
Specification (revision 2.0).
For information about Module Status LED indications during power-up, refer to
Section 8.2.4 of the DeviceNet Specification (revision 2.0).
4-10
the state indicated is
No power
Off
Operational
Standby
Unrecoverable Fault
Device Self-Testing
I/O Communication and Control
which means that
the unit is not receiving
power.
the unit is operating
normally.
the unit needs
maintenance because the
configuration is missing,
incomplete, or incorrect.
the unit has experienced a
fault from which it
cannot recover; you may
need to replace the unit.
the unit is running self
diagnostics
5702156-E