Pinnacle™ 20 kW
Target Type: Non-Metal
Use the non-metal setting if your target is, for example, silicon or carbon. Indicating a
non-metal target, pre-selects an arc detect delay time of 0 ms during a normal process
cycle and 20 µs during the TCC (320 µs when slow arc response is selected); it sets an
arc shutdown time of 500 µs during both a normal cycle and the TCC (8000 µs when
slow arc response is selected). You can select target type through the ARC menu on
5702156-E
Operation