11 Wireless LAN Controller
192
Field
Max. number of clients
- soft limit
Client Band select
Description
less module depends on the specifications of the respective
WLAN module. This maximum is distrubuted across all wireless
networks configured for this radio module. No more new wire-
less networks can be created and a warning message will ap-
pear if the maximum number of clients is reached.
Possible values are whole numbers between
The default value is
.
Not all devices support this function.
To avoid a radio module being fully utilised, you can set a "soft"
restriction on the number of connected clients. If this number is
reached, new connection queries are initially rejected. If the cli-
ent cannot find another wireless network and, therefore, repeats
its query, the connection is accepted. Queries are only definit-
ively rejected when the Max. number of clients - hard limit is
reached.
The value of the Max. number of clients - soft limit must be
the same as or less than that of the Max. number of clients -
hard limit.
The default value is
.
You can disable this function if you set Max. number of clients
- soft limit and Max. number of clients - hard limit to identical
values.
Not all devices support this function.
This function requires a dual radio setup where the same wire-
less networkis configured on both radio modules, but in different
frequency bands.
The Client Band select option enables clients to be moved
from the frequency band originally selected to a less busy one,
providing the client supports this. To achieve a changeover, the
connection attempt of a client is initially refused so that the cli-
ent repeats the attempt in a different frequency band.