ASCII (Telnet)
Command
(Host to Processor)
Ethernet Data Port
E
Set current
0 *
connection port
timeout
View current
E
0TC
connection port
timeout
Set global IP port
E
1 *
timeout
View global port
E
1TC
timeout
Firmware Version Requests
NOTES:
•
An asterisk (*) after the version number in these commands indicates which version is currently running. A caret (^)
indicates bad checksum or invalid load. Question marks (?.??) indicate that the firmware version is not loaded.
•
In firmware version request command responses, the WindoWall Pro names are shown as MGP 464 Pro or
MGP 464 DI Pro.
Query firmware
Q or 1Q
version
Example:
1Q
Query verbose
0Q
version information
Example:
0Q
Query bootstrap
2Q
version
URL Encoded (Web)
(Host to Processor)
X13*
}
X13*
TC
W 0 %2A
}
|
W 0TC
X13*
}
X13*
TC
W 1 %2A
}
|
W 1TC
Q or 1Q
1Q
0Q
0Q
3.46-1.00(1.81-MGP464 PRO -Wed, 16 Jan 2003 00:00:00 GMT)
-1.00*(1.82-MGP464 PRO -Thu, 28 Feb 2003 07:18:07 GMT)
2Q
WindoWall Pro Series • Remote Configuration and Control
Response
(Processor to Host)
|
X13* ]
TC
Pti 0 *
X13* ]
|
X13* ]
TC
Pti 1 *
X13* ]
X10$ ]
With tagged
response – verbose
modes 2 and 3:
X10$ ]
Ver01 *
1.01
Sum of responses
from 2Q-3Q-4Q
With tagged
response – verbose
modes 2 and 3:
Ver00 * Sum of
responses from
]
2Q-3Q-4Q
(See below.)
X10$ ]
With tagged
response – verbose
modes 2 and 3:
X10$ ]
Ver02 *
Additional Description
Set number of seconds (in
tens of seconds) before
timeout on the current IP
connection only.
X13*
= 1-32767.
Default is 30 = 300 seconds
= 5 minutes.
Set number of seconds (in
tens of seconds) before
timeout on all IP connections
made from this processor.
X13*
= 1-32767.
Default is 30 = 300 seconds
= 5 minutes.
Show the WindoWall Pro
firmware version number
X10$
to two decimal places.
Gives the number of the
currently running version of
the user-updatable firmware.
Show bootstrap, factory-
]
installed, and updated
firmware versions (see 2Q,
3Q, and 4Q commands on
the following lines).
The bootstrap firmware is
not user-replaceable, but you
may need this information for
troubleshooting.
42