(2) The basic rotation cycle of the toner sensor is as follows:
Basic rotation cycle of toner sensor
Toner low time
Toner full time
Copyright 1998, Okidata, Division of OKI America, Inc. All rights reserved. See the OKIDATA Business Partner
Exchange (BPX) for any updates to this material. (http://bpx.okidata.com)
T time
4.9 sec.
t1 > 1.2 sec.
1.2 sec. > t1 >