Oki OKIOFFICE84 Regulatory Information
Oki OKIOFFICE84 Regulatory Information

Oki OKIOFFICE84 Regulatory Information

Warranty, regulatory information, and specifications

Advertisement

Warranty,
Regulatory Information,
and Specifications

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OKIOFFICE84 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Oki OKIOFFICE84

  • Page 1 Warranty, Regulatory Information, and Specifications...
  • Page 2 Every effort has been made to ensure that the information in Okidata and OKI are registered trademarks of Oki Electric this document is complete, accurate, and up-to-date. Industry Company, Ltd.; marques déposés de Oki Electric OKIDATA assumes no responsibility for the results of errors Industry Company, Ltd.;...
  • Page 3: Table Of Contents

    Contents Overview Regulatory Information ..........19 Year 2000 Compliance ........... 4 ..............4 Federal Communications Commission (FCC) NERGY Requirements for End Users ........19 Limited Warranty ............5 FCC Telephone Consumer Protection Act ....20 Limited Warranty: U.S. and Canada ....... 5 Industry Canada (IC) Requirements for End Users ..
  • Page 4: Year 2000 Compliance

    Year 2000 Compliance ® NERGY The OKIOFFICE 84 is Year 2000 Compliant. It contains information technology that accurately processes date and time data between the years 1999 and 2000, and carries no issue for the September 9, 1999 (9999) programming concern.
  • Page 5: Limited Warranty

    Limited Warranty Overview Limited Warranty: U.S. and Canada shipping prepaid, in the original shipping container or equivalent, to Okidata or an authorized Okidata service center and assume the risk of loss or damage in transit. A written Okidata, Division of Oki America, Inc. (Okidata) warrants receipt for the product, showing the date and location of this OKIOFFICE 84 to be free from defect in material and purchase, and both the model and serial numbers of this...
  • Page 6 FITNESS FOR A PARTICULAR PURPOSE, SHALL This Limited Warranty applies to this OKIOFFICE 84. EXTEND BEYOND THE RESPECTIVE WARRANTY However, the procedure for obtaining service may vary PERIOD DESCRIBED ABOVE. Some states do not allow outside the continental United States. Contact your Okidata limitations on how long an implied warranty lasts, so the dealer for such warranty service information.
  • Page 7: Limited Warranty: Latin America

    Oki cartridges, fuses, etc. Data service center. Oki Data will repair (or at its option replace) at no charge, THERE ARE NO EXPRESS WARRANTIES OTHER THAN any defective component(s) of the Product for one (1) year...
  • Page 8: Overnight Exchange

    Overnight Exchange Overview Available in the United States and Canada. exchange unit: failure to do so may result in your being charged the full price of the exchange unit. Before you ship the OKIOFFICE 84, remove the image drum and toner cartridge to prevent damage to the OKIOFFICE 84 during If you choose to use our Overnight Exchange service, call shipment: failure to do so may result in a fee for cleaning/...
  • Page 9: How To Activate Your Okioffice 84 Overnight

    an authorized service center or authorized third party service American Express; this program is not available organization. Call 1-800-OKIDATA (1-800-654-3282) for outside the U.S. & Canada.) authorized service locations using our depot repair program. This information is kept confidential, and will only be used if the returned unit is not received, if How to activate your OKIOFFICE 84 no receipt is supplied confirming that the...
  • Page 10 repaired/reconditioned “as new” machine and will require replacement of consumables—image drum and toner cartridge—from the original unit. 5 Return the original unit—reuse the packing material from the exchange unit. Follow the enclosed instructions to schedule the return shipment—there is no additional cost.
  • Page 11: Okidata Service Centers

    Okidata Service Centers Overview For the most up-to-date listing of Okidata Service Centers: • Consult our web site at www.okidata.com • In the U.S. and Canada, call 1-800-OKIDATA (1-800-654-3282) • In Latin America, contact the Latin America Service Coodinator at Okidata's Corporate Headquarters at 609-222-5276 (Spanish only) United States Canada...
  • Page 12 Phone: 55-11-5011-1518 Fax: 56 (2) 550-2399 Fax: 571-616-1386 Fax: 55-11-5012-0267 Mexico Peru Venezuela Oki Data de Mexico, S.A. de C.V. Teknos Comunicaciones Intercal Servicios C.A. Av. Insurgentes 1700 – 7 Piso Los Sauces 325 RIF: J-30406985-5 Col. Florida 01030 San Isidro, Lima 27, Peru...
  • Page 13: Specifications

    Specifications Overview Printing Faxing (continued) Print speed 8 pages per minute One Touch/Auto 10/70 Dials Print resolution 600 dpi class output in Windows Dialing groups 5 (up to 80 numbers each) Method LED, toner based Broadcast 90 locations transmissions Faxing Modem speed 14.4 Kbps Protocol...
  • Page 14 Copying Interface Copy speed 8 copies per minute Standard IEEE 1284 bi-directional parallel (cable included) Number of 50 maximum from single original copies PC requirements 486/33MHz or higher; Windows 3.1/3.11, Windows 95, Windows 98, Automatic feeder Up to 20 originals or Windows NT 4.0;...
  • Page 15 Environmental Dimensions 12.3 x 15.3 x 7.5" (31.1 x 38.7 x 19.0 (W x D x H) cm), excluding paper tray Weight 16 lb. 12 oz (7.6 kg) with image drum Power 120 VAC ± 10%, 50/60 Hz ± 2% or 220/240 VAC ±...
  • Page 16: Safety Information

    Safety Information Overview Installation Hints • The power outlet should be located near the equipment and should be easily accessible. • The TEL port on the back of the unit is only suitable for • Install your OKIOFFICE 84 MFP in a dust-free location 2-wire devices.
  • Page 17: Toner Cartridge And Image Drum Unit Handling

    Toner Cartridge and Image Drum Unit • Disconnect the power cord before trying to remove any objects that may have fallen into the machine. Handling • When relocating your MFP, always disconnect the telephone line before disconnecting the power cord, then •...
  • Page 18: Emergency First Aid

    Emergency First Aid • If toner is swallowed: Dilute by giving two glasses of water and induce vomiting by administering Syrup of Ipecac (follow manufacturer’s instructions). Seek medical attention. Never attempt to induce vomiting or give anything by mouth to a person who is unconscious. •...
  • Page 19: Regulatory Information

    Regulatory Information Overview Federal Communications Commission 2 The following USOC jacks may be used with this equipment: RJ11C. (FCC) Requirements for End Users 3 The REN is used to determine the quantity of devices which may be connected to the telephone line. Excessive This device has been granted a registration number by the REN’s on the telephone line may result in the devices not Federal Communications Commission, under Part 68 rules...
  • Page 20: Fcc Telephone Consumer Protection Act

    5 The telephone company may make changes in its facilities, 8 This equipment cannot be used on public coin service equipment, operations, or procedures that could affect the provided by the telephone company. Connection to Party operation of the equipment. If this happens, the telephone Line Service is subject to state tariffs.
  • Page 21: Industry Canada (Ic) Requirements For End Users

    To comply with this law, you must enter the following line individual service may be extended by means of a information in your fax unit: certified connector assembly (telephone extension cord). The customer should be aware that compliance with the above •...
  • Page 22: Fcc Radio Frequency Interference Statement For 120-Volt Models

    The Load Number assigned to each terminal device denotes try to correct the interference by one or more of the following the percentage of the total load to be connected to a telephone measures: loop which is used by the device, to prevent overloading. The •...
  • Page 23: Fcc Radio Frequency Interference Statement For 230/240-Volt Models

    FCC Radio Frequency Interference IC Radio Interference Statement for Statement for 230/240-Volt Models 230/240-Volt Models WARNING: This equipment has been tested and found to This OKI apparatus complies with the Class A limits for radio comply with the limits for a Class A digital device, pursuant interference as specified in the Industry Canada Radio to Part 15 of the FCC Rules.
  • Page 24: Material Safety Data Sheet

    Material Safety Data Sheet Overview OKIOFFICE 84 Toner (Type 6), P/N 52111701 Toner inhaled MSDS #58331801 Remove person to fresh air. Seek medical attention. For more information, contact Okidata at: Toner gets in the eyes 2000 Bishops Gate Boulevard Flush eyes with large quantities of cool water for 15 minutes, Mount Laurel, NJ 08054-4620 keeping the eyelids open with fingers.
  • Page 25 Hazardous Ingredients This product is not regulated under Section 313 of SARA, Title III. Styrene-Butyl Acrylate Copolymer (91% by weight) CAS# 25767-47-9 Physical Data OSHA TWA 15 mg/m for total dust Melting Point: 110°C (230°F) ACGIH TLV 10 mg/m for total dust Boiling Point: Not applicable Vapor Pressure: Not applicable Carbon Black (5-7% by weight)
  • Page 26 Fire and Explosion Hazard Data Health Hazards Data Flash Point (Method Used): Not applicable Routes of Entry: Inhalation, Ingestion, Eyes, Skin. Flammable Limits 1 Styrene-Butyl Acrylate Copolymer Lower Explosive Limit: Not applicable Subcutaneous implantation of polymeric styrene powder Upper Explosive Limit: Not applicable in rats has induced tumors at the site of implantation.
  • Page 27 Spill Cleanup and Disposal 4 Amorphous Fumed Silica (Group 3 “Not Classifiable”; IARC) Spill Cleanup Overexposure to amorphous silica has been associated Small Spills with causing irritation of the lungs and pneumoconiosis. 1 Remove sources of ignition. Long-term inhalation exposure may be associated with producing tumors in laboratory animals.
  • Page 28 Safe Handling and Use The information contained in this MSDS is based on data Respiratory Protection: Not normally required. For large considered accurate; however, no warranty is expressed spills, use NIOSH-approved full face-piece respirator with or implied regarding the accuracy of these data or the HEPA cartridge during cleanup.

This manual is also suitable for:

Okioffice 84

Table of Contents