Use the cleaning kit
In case the internal section is dirty or if nozzle missing cannot be resolved even after cleaning (
page 2.32, 4.10), use the cleaning kit.
The cleaning kit contains the following items. Do not use alcohol or water.
When using the supplied maintenance cleaning fluid, be sure to wear the supplied protective glasses.
• Cleaning fluid RS for maintenance (SPC-0336)
• Dropper
• Cotton bud
• Glove
Cleaning the station interior
STEP
1. Push the [FUNCTION] key.
2. Push the [ ] and [ ] key until the display gives
the indication [MAINTENANCE].
3. Push the [ENTER] key.
[STATION] is displayed.
4. Push the [ENTER] key.
[CARRIAGE out] is displayed.
5. Push the [ENTER] key.
Move the carriage on the platen.
6. Open the front cover.
7. Dampen a cotton bud with cleaning fluid.
8. Using the cotton bud dampened with cleaning
fluid, wipe out dirt on the wiper and around the
cap.
9. Close the front cover, and push the [ENTER]
key.
The carriage return to the capping station, and the initial
operation is performed.
Downloaded From ManualsPrinter.com Manuals
•
Be careful not to leave lint of the cotton bud. Lint
may cause plotting failure.
FUNCTION
SET UP
FUNCTION
MAINTENANCE
MAINTENANCE
STATION
STATION
MENT : CARRIAGEout
STATION
COMPLETED
< LOCAL >
- 3.6 -
< ENT >
< ENT >
< ent >
: ent