Use the cleaning kit

In case the internal section is dirty or if nozzle missing cannot be resolved even after clean-
ing (
page 2.23, 4.10), use the cleaning kit.
The cleaning kit contains the following items. Do not use alcohol or water.
When using the supplied maintenance cleaning fluid, be sure to wear the supplied protec-
tive glasses.
Cleaning fluid RS for maintenance (SPC-0336)
Dropper
swab
Glove

Cleaning the station interior

STEPS:
1. Press the [FUNCTION] key in the LOCAL mode.
2. Press the Jog key [ ] or [ ] to select the
[MAINTENANCE].
3. Press the [ENTER] key.
[STATION] is displayed.
4. Press the [ENTER] key.
[CARRIAGE out] is displayed.
5. Press the [ENTER] key.
Move the carriage on the platen.
6. Open the front cover.
7. Using the swab dampened with cleaning fluid,
wipe out dirt on the wiper and around the cap.
Be careful not to leave lint of the swab. Lint may
cause plotting failure.
9. Close the front cover.
10. Press the [ENTER] key.
The carriage return to the capping station, and the initial
operation is performed.
- 3.7 -
FUNCTION
SET UP
< ENT >
FUNCTION
MAINTENANCE
< ENT >
MAINTENANCE
STATION
< ent >
STATION
MENT : CARRIAGEout