Polaris msx 110 Service Manual page 144

Four stroke personal watercraft
Table of Contents

Advertisement

FUEL INJECTION / IGNITION / EXHAUST SYSTEMS
Lambda Sensor Circuit
ECU 300 (Black)
A
B
C
D
E
F
G
H
4
3
2
1
A
B
C
D
E
F
G
H
J
K
L
M
3
1
A
B
C
D
E
F
G
H
4
3
2
1
ECU 100 (Grey)
Circuit Trouble Codes
P - - Code
P0030
Heated Oxygen Sensor Circuit: Open Load
P0031
Heated Oxygen Sensor Circuit: Short to Ground
P0032
Heated Oxygen Sensor Circuit: Short to Battery
P0130
Oxygen Sensor Circuit: Signal Error
P0131
Oxygen Sensor Circuit: Plausibility Error
P0132
Oxygen Sensor Circuit: Short to Battery
P0133
Oxygen Sensor Circuit: Slow Response
P0134
Oxygen Sensor Circuit: Low Output
P0135
Heated Oxygen Sensor Circuit: Plausibility Error
2004 Four Stroke PWC Service Manual
O2 Heating Control
E2
O2 Heating Power
4
2
O2 Signal
A3
B3
O2 Ground
Description
1
1
2
2
3
3
4
4
Summary
The O2 heater circuit is open.
The O2 heater circuit is shorted to ground.
The O2 heater circuit is shorted to battery voltage.
TBD
Indicates the O2 sensor signal is outside an acceptable range.
Indicates the O2 sensor signal is too high.
The O2 sensor signal is slow to respond to fuel mixture changes.
The O2 sensor signal has not changed for a long period of time.
The O2 sensor signal is outside an acceptable range.
Relay
To Main
Terminal 13
O2
Exhaust
5.19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Msx 150

Table of Contents