Appendix B: Rfp Power Consumption - ASCOM IPBS Installation And Operation Manual

Ip-dect base station & ip-dect gateway
Table of Contents

Advertisement

Installation and Operation Manual
IP-DECT Base Station & IP-DECT Gateway (software version 5.0.x)

Appendix B: RFP Power Consumption

The tables below show power consumption for a base station connected to and powered
from the IPBL. The power consumption of the IPBL is approximately 15 W.
The maximum cable length for base stations connected to the IPBL must not exceed 1500
meters.
B.1
KRCNB 201/DCT1800
Figure 3.
Cable
length
(metres)
1000
1100
1200
1300
1400
1500
Table 1 Power consumption (watts) of base stations and cabling when powered from the IPBL.
15 February 2012 / Ver. H
0.4 mm wire size (∅)
Without
With
EPP
EPP
0
7.5
7.5
100
7.9
7.8
200
8.3
8.0
300
8.9
8.3
400
9.8
8.7
500
11.3
9.2
600
-
9.8
700
-
10.7
800
-
12.3
900
-
-
-
-
-
-
-
-
-
-
-
-
-
-
0.5 mm wire size (∅)
0.6 mm wire size (∅)
Without
With
Without
EPP
EPP
EPP
7.5
7.5
7.5
7.8
7.7
7.7
8.0
7.8
7.8
8.3
8.0
8.0
8.7
8.2
8.2
9.2
8.5
8.4
9.8
8.7
8.6
10.7
9.0
8.8
12.3
9.4
9.1
-
9.8
9.5
-
10.3
9.9
-
11.1
10.4
-
12.3
11.1
-
-
12.1
-
-
-
-
-
-
TD 92579EN
With
EPP
7.5
7.6
7.7
7.8
7.9
8.0
8.2
8.3
8.4
8.6
8.8
8.9
9.1
9.3
9.6
9.9
153

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IPBS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

Ipbl

Table of Contents

Save PDF