• Detailed Settings for Search Position Compensation
The settings for the Search Position Compensation item are almost the same as those for the Search
inspection item. (The [Multi-point output] and model parameter settings of the Search inspection item are not
included in the Search Position Compensation settings.) Make the settings for teaching and the judgement
conditions in the same way as for the Search item. (
148)
Also, the following settings are included only in the Search Position Compensation Item.
• Source Image
You can select the image to which to apply the results of position compensation processing.
Applying the Results of Position Compensation: p. 83
• Interpolation
You can select the precision of position compensation.
If you select [Bilinear], the precision of position compensation will increase.
[Image] − [Image adjustment] − [Search position comp.] − [Modify] − [Details] −
[Scroll parameter] − [Interpolation]
The settings are the same as those for the Shape Search Position Compensation item.
Interpolation: p. 85
• Measurement Data That Can Be Used for External Outputs and Calculations
The following values can be used as measurement data and output to external devices via Ethernet or used in
calculations.
Expression text string
Data name
JG
Judgement
DX
Scroll X
DY
Scroll Y
X
Position X
Y
Position Y
SX
Reference X
SY
Reference Y
CR
Correlation
FQ2-S/CH User's Manual
4-8 Inspecting with the Search Inspection Item: p.
Description
This is the judgement result.
This is the amount of position com-
pensation for the X coordinate.
This is the amount of position com-
pensation for the Y coordinate.
This is the X coordinate of the position
where the model was found.
This is the Y coordinate of the position
where the model was found.
This is the X coordinate of the position
where the model was registered.
This is the Y coordinate of the position
where the model was registered.
This is the correlation.
Data range
−2: No judgement (not measured),
0: Judgement is OK,
−1: Judgement is NG,
−15: Out of range error
−99,999.9999 to 99,999.9999
−99,999.9999 to 99,999.9999
−99,999.9999 to 99,999.9999
−99,999.9999 to 99,999.9999
−99,999.9999 to 99,999.9999
−99,999.9999 to 99,999.9999
0 to 100
Adjusting the Images That Were Taken