Omron FQ2-S Series User Manual page 315

Smart camera
Hide thumbs Also See for FQ2-S Series:
Table of Contents

Advertisement

Menu command
Edge pitch
Average pitch
Max. pitch (max-
imum pitch)
Min. pitch (mini-
mum pitch)
Average width
Max. width
(maximum pitch)
Min. width (mini-
mum pitch)
Color difference
(Color images
only)
Color deviation
(Color images
only)
R average
(Color images
only)
G average
(Color images
only)
B average
(Color images
only)
Density aver-
age (mono-
chrome images
only)
Density deviat.
(monochrome
images only)
Area
Gravity X
Gravity Y
FQ2-S/CH User's Manual
Description
Sets the Edge pitch OK range.
Sets the upper and lower limits of the
difference between the average color
and reference color that is to be
judged as OK.
Set the upper and lower limits of the
range of the deviation in the region
that is to be judged as OK.
Set the difference in the average value
of the R (red) component that is to be
judged as OK.
Set the difference in the average value
of the G (green) component that is to
be judged as OK.
Set the difference in the average value
of the B (blue) component that is to be
judged as OK.
Sets the upper/lower limit range for the
density average in the measurement
region.
Sets the upper/lower limit range for the
density deviation in the measurement
region.
Set the upper and lower limits for an
OK judgement.
Set the upper and lower limits of the
range of gravity X that is to be judged
as OK.
Set the upper and lower limits of the
range of the gravity Y that is to be
judged as OK.
Setting range
Range: 0 to 1000
Defaults: Lower limit: 0, Upper limit:
1000
Range: 0.0000 to 99,999.9999
Defaults: Lower limit: 0.0000, Upper
limit: 99,999.9999
0.0000 to 442.0000
(Defaults: Lower limit: 0, Upper limit:
442)
0.0000 to 221.0000
(Defaults: Lower limit: 0, Upper limit:
221)
0.0000 to 255.0000
(Defaults: Lower limit: 0, Upper limit:
255)
0.0000 to 255.0000
(Defaults: Lower limit: 0, Upper limit:
255)
0.0000 to 255.0000
(Defaults: Lower limit: 0, Upper limit:
255)
0 to 255
(Defaults: Lower limit: 0, Upper limit:
255)
0 to 127
(Defaults: Lower limit: 0, Upper limit:
127)
• When the result type is set to abso-
lute value:
Range: 0.0000 to 999,999,999.9999
Defaults: Upper limit: 999,999,999.9999,
Lower limit: 0.0000
• When the result type is set to relative
values:
Range: −999,999,999.9999 to 999,999,999.9999
Defaults: Upper limit: 999,999,999.9999,
Lower limit: −999,999,999.9999
• When the result type is set to ratios:
Range: 0.0000 to 999.9999(%)
Defaults: Upper limit: 999.9999,
Lower limit: 0.0000
Range: −99,999.9999 to 99,999.9999
Defaults: Upper limit: 99,999.9999,
Lower limit: −99,999.9999
Range: −99,999.9999 to 99,999.9999
Defaults: Upper limit: 99,999.9999,
Lower limit: −99,999.9999
Data
Refer-
ence
Scene
p. 188
Scene
Scene
Scene
Scene
Scene
Scene
Scene
p. 193
Scene
Scene
Scene
Scene
Scene
Scene
Scene
p. 199
Scene
Scene