Omron FQ2-S Series User Manual page 357

Smart camera
Hide thumbs Also See for FQ2-S Series:
Table of Contents

Advertisement

External
Category Data name
refer-
ence
number
132
Judge-
Similarity judgement
ment
upper limit
condi-
133
Similarity judgement
tions
lower limit
134
Stability judgement
upper limit
135
Stability judgement
lower limit
136
Output
Line delimiter
parame-
ter
138
String output ON/OFF
139
NG error code output
*1
141
Error string
142
Partial output ON/OFF
143
Output end digit
144
Output beginning digit
146
Mea-
Reading mode
sure-
ment
*1
150
Format character string
condi-
0
tions
*1
151
Format character string
1
*1
152
Format character string
2
*1
153
Format character string
3
160
Output
Dictionary registration
parame-
processing unit
ter
170
String output ON/OFF
(memory link)
171
NG error code output
(memory link)
172
Partial output ON/OFF
(memory link)
173
Output end digit (mem-
ory link)
174
Output beginning digit
(memory link)
191
Mea-
Character width lower
sure-
limit
ment
192
Character height lower
condi-
limit
tions
193
Character width upper
limit
194
Character height upper
limit
FQ2-S/CH User's Manual
Setting/Acqui-
Data range
sition
Setting/Acqui-
0 to 100
sition
Setting/Acqui-
0 to 100
sition
Setting/Acqui-
0 to 100
sition
Setting/Acqui-
0 to 100
sition
Setting/Acqui-
0: None, 1: Comma, 2:
sition
Space
Setting/Acqui-
0: OFF, 1: ON
sition
Setting/Acqui-
0: OFF, 1: ON
sition
Setting/Acqui-
20 characters max.
sition
Setting/Acqui-
0: OFF, 1: ON
sition
Setting/Acqui-
1 to 128
sition
Setting/Acqui-
1 to 128
sition
Setting/Acqui-
0: Fixed, 1: Variable
sition
Setting/Acqui-
32 characters max.
sition
Setting/Acqui-
32 characters max.
sition
Setting/Acqui-
32 characters max.
sition
Setting/Acqui-
32 characters max.
sition
−1: None or 0 to 31
Setting/Acqui-
sition
Setting/Acqui-
0: OFF, 1: ON
sition
Setting/Acqui-
0: OFF, 1: ON
sition
Setting/Acqui-
0: OFF, 1: ON
sition
Setting/Acqui-
1 to 128
sition
Setting/Acqui-
1 to 128
sition
Setting/Acqui-
0 to 9999
sition
Setting/Acqui-
0 to 9999
sition
Setting/Acqui-
0 to 9999
sition
Setting/Acqui-
0 to 9999
sition
Default
Expres-
Logged data/
sion text
Judgement
string
parameter
100
---
Judgement
condition
60
---
Judgement
condition
100
---
Judgement
condition
10
---
Judgement
condition
0
---
---
0
---
---
1
---
---
NG
---
---
0
---
---
128
---
---
1
---
---
0
---
---
---
---
---
---
---
---
---
---
−1
---
---
0
---
---
1
---
---
0
---
---
128
---
---
1
---
---
0
---
---
0
---
---
9999
---
---
9999
---
---
External Reference Parameters
355

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fq2-ch seriesFq2-s/ch series

Table of Contents