Labeling (Fq2-S1/S2/S3 Series Or Fq2-S4 Series Only) - Omron FQ2-S Series User Manual

Smart camera
Hide thumbs Also See for FQ2-S Series:
Table of Contents

Advertisement

Labeling (FQ2-S1/S2/S3 series or FQ2-S4 series only)

External
Category Data name
refer-
ence
number
0
Mea-
Judgement
sure-
ment
result
5
Number of labels
6
Area
7
Gravity center X
8
Gravity center Y
9
Reference area
10
Reference position X
11
Reference position Y
15
Total label area
55
Master angle
103
Output
Reflect
parame-
ter
127
Extracte
Background color
d image
display
condition
131
Set color Area color inversion
Binary
132
Mea-
Filling up holes
sure-
ment
133
Outside trimming
condi-
tions
136
Label sort condition
146
Binary
Binary level upper limit Setting/Acqui-
level
147
Binary level lower limit
388
External Reference Parameters
Setting/Acqui-
Data range
sition
−2: No judgement (not mea-
Acquisition
only
sured),
0: Judgement is OK,
−1: Judgement is NG,
−13: Teaching not performed
error,
−14: Figure not registered error,
−15: Out of range error
Acquisition
0 to 100
only
Acquisition
0 to 999,999,999.9999
only
−99,999.9999 to 99,999.9999
Acquisition
only
−99,999.9999 to 99,999.9999
Acquisition
only
Acquisition
0 to 999,999,999.9999
only
−99,999.9999 to 99,999.9999
Acquisition
only
−99,999.9999 to 99,999.9999
Acquisition
only
Acquisition
0 to 999,999,999.9999
only
−180 to 180
Acquisition
only
Setting/Acqui-
0: Yes, 1: No
sition
Setting/Acqui-
0: Black, 1: White, 2: Red, 3:
sition
Green, or 4: Blue
Setting/Acqui-
0: None or 1: Enabled
sition
The binary value is displayed for
a Monochrome Camera.
Setting/Acqui-
0: No, 1: Yes
sition
Setting/Acqui-
0: No, 1: Yes
sition
Setting/Acqui-
0: Ascending order of area,
sition
1: Descending order of area,
2: Ascending order of gravity X,
3: Descending order of gravity
X,
4: Ascending order of gravity Y,
5: Descending order of gravity Y
0 to 255
sition
Setting/Acqui-
0 to 255
sition
Default
Expres-
Logged data/
sion text
Judgement
string
parameter
−2
JG
Logged data
0
L
Logged data
0
AR[0] to
Logged data
AR[99]
0
X[0] to
Logged data
X[99]
0
Y[0] to
Logged data
Y[99]
0
SA
---
0
SX
---
0
SY
---
0
TAR
Logged data
0
ATH[0] to
Logged data
ATH[99]
0
---
---
0
---
---
0
---
---
0
---
---
0
---
---
1
---
---
255
---
---
128
---
---
FQ2-S/CH User's Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fq2-ch seriesFq2-s/ch series

Table of Contents