Product
Model number
FQ Vision Sensor
FQ2-S@@@@@@-@@@
FQ2-S@@-@@@
FQ2-CH1@@@@@-M
Touch Finder
FQ2-D@@
PC Tool
---
Parallel Interface
FQ-SDU1@
*1
Sensor Data Unit
RS-232C Interface
FQ-SDU2@
*1
Sensor Data Unit
FQ Ethernet Cable
FQ-WN0@@
Standard RJ45
---
*2
Ethernet Cable
I/O Cable
FQ-WD0@@
Switching Hub
W4S1-0@@
Sensor Data Unit
FQ-WU0@@
cable
Parallel cable for
FQ-VP1@@@
FQ-SDU1
Parallel cable for
FQ-VP2@@@
FQ-SDU2
RS-232C cable
Recommended:
(to connect to a
XW2Z-200S-V (2 m) or
PLC)
XW2Z-500S-V (5 m)
*1:
FQ2-S1@@@@@ and FQ2-S2@@@@@ are not supported.
*2:
The shape and dimensions of the Ethernet connector plug and jack are specified in ISO/IEC8877:1992 (JIS X 5110:1996) and RJ-45 of
the FCC regulations. To prevent connector connection failures, the structure of the jack of this product does not allow insertion of plugs that
do not comply with the standard. If a commercially available plug cannot be inserted, it is likely that the plug is non-compliant.
Important
Do not connect network devices other than PLCs on the same network as the Touch Finder or computer. If another
device is connected, the responsiveness of displays and settings of the Touch Finder or computer may become slow.
FQ2-S/CH User's Manual
Remarks
This is the Vision Sensor.
This is a setup console.
The PC Tool can be used instead of the Touch Finder. If you register as a member,
you can download the free PC Tool as a special service to purchasers.
Refer to the Member Registration Sheet that is enclosed with the Sensor for the
member registration procedure and the download procedure for special member soft-
ware.
You can connect a Sensor Data Unit to the I/O cable connector on the Vision Sensor
and connect the Parallel Interface Sensor Data Unit to an external device. This allows
you to output the results of judgement conditions, measurements from inspection
items, and the results of expressions with parallel communications.
You can connect a Sensor Data Unit to the I/O cable connector on the Vision Sensor
and connect the RS-232C Interface Sensor Data Unit to an external device. This
allows you to use no-protocol communications to send and receive commands,
inspection item parameters, and other data between the Sensor and the external
control device that is connected with the RS-232C cable. You can also use the ACK
signal (parallel command normal completion signal) for a parallel output from the
Sensor Data Unit.
Connects the Sensors to external devices such as the Touch Finder, computers, and
PLCs.
Connects the Switching Hub to the Touch Finder, computers, and PLCs. Use a con-
nector that complies with the FCC RJ45 standard. (STP (shielded twisted-pair) cable,
category 5e or 6, impedance: 100 Ω)
Connects the Sensor to the power supply and external devices.
Used to connect multiple Sensors to one Touch Finder or PC Tool.
This cable connects the FQ2-S3/S4/CH Sensor to the Sensor Data Unit.
This cable connects the Parallel Interface Sensor Data Unit to an external device.
This cable connects the RS-232C Interface Sensor Data Unit to an external device.
This cable connects the RS-232C Interface Sensor Data Unit to an external device.