Omron FQ2-S Series User Manual page 258

Smart camera
Hide thumbs Also See for FQ2-S Series:
Table of Contents

Advertisement

11
The calibration parameters will be displayed.
The items in the calibration parameters are listed in the
following table.
Item
Setting
A
Calculated value
B
Calculated value
C
Calculated value
D
Calculated value
E
Calculated value
F
Calculated value
Reference
With this method, the calibration settings are based on measurement results.
When you enter the actual coordinates of the position that results from searching for a registered model, the
calibration parameters are calculated automatically. (The position resulting from the search is found at the
subpixel level.)
Model
(Setup Mode) − [Calibration]
1
Select the data region to set from [Calibration data 0]
to [Calibration data 31].
2
Press [Modify].
3
[ ] −
Press
4
Press [No. 1] and then press [Modify].
256
Calibration
Description
These are the calibration conversion values.
These values are used to convert the Camera coordinates to the actual coordinates.
The following formulas are used to convert to actual coordinates.
• (X,Y): Camera coordinates of measurement position, Unit: pixels
• (X',Y'): Converted coordinates (actual coordinates)
X' = A × X + B × Y + C
Y' = D × X + E × Y + F
[Reference] on the right of the display.
Measure three positions and enter the actual coordinates of them.
FQ2-S/CH User's Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fq2-ch seriesFq2-s/ch series

Table of Contents