Reflect In Total Judgement - Omron FQ2-S Series User Manual

Smart camera
Hide thumbs Also See for FQ2-S Series:
Table of Contents

Advertisement

Step 3
Adjusting Judgement Parameters
− [Inspection]
[Inspect]
1
Press [Judgement].
2
Press the parameters and set the range that is to be
judged as OK.
The measured value is displayed beside the parameter
name. Continuous measurements will be performed for
the images that are displayed.
Note
You can change the parameters for judgement conditions on the
Display Settings Display. Press
of the display to switch to the Display Settings Display.
3
Press [OK] to enter the value.
Item
Parameter
Judgement Parameter
Area
Gravity X
Gravity Y
Note
• You can change the output form for each measurement value to one of the following settings.
− [Result type] on the right of the display.
[
]
Press
Absolute value (default): The measured coordinates are output.
Relative value: The difference from the reference position is output as coordinates.
Ratio: The percentage of the reference value is output. (This applies to the area only.)

Reflect in Total Judgement

You can specify whether to reflect the judgement results of an inspection item in the overall judgement. (The
default is to reflect them.)
[Inspect]
[Inspection]
FQ2-S/CH User's Manual
− [Add item.] − [Area] − [Settings] Tab Page
− [Display setting] on the right
[
]
Setting
When the result type is set to absolute
value
Range: 0.0000 to 999,999,999.9999
Defaults: Upper limit: 999,999,999.9999,
Lower limit: 0.0000
When the result type is set to relative
value
Range: −999,999,999.9999 to 999,999,999.9999
Defaults: Upper limit: 999,999,999.9999,
Lower limit: −999,999,999.9999
When the result type is set to ratio
Range: 0.00000 to 999.9999
Defaults: Upper limit: 999.9999,
Lower limit: 0.0000
Range: −99,999.9999 to 99,999.9999
Defaults: Upper limit: 99,999.9999,
Lower limit: −99,999.9999
Range: −99,999.9999 to 99,999.9999
Defaults: Upper limit: 99,999.9999,
Lower limit: −99,999.9999
[Add item.]
[Area]
Lower limit
Blue for OK. Red for NG.
Description
Set the upper and lower limits for an OK
judgement. The set range is the differ-
ence between the reference area and
the measured areas.
Set the upper and lower limits of the
range of gravity X that is to be judged
as OK.
Set the upper and lower limits of the
range of the gravity Y that is to be
judged as OK.
[Details] Tab Page
[Output parameter]
Inspecting with the Area Inspection Item
Upper limit
199

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fq2-ch seriesFq2-s/ch series

Table of Contents