2-5 Setting Up Ethernet
FQ2-S1
FQ2-S2
FQ2-S3
Connecting to Sensors from the Touch Finder
Configurations Consisting of Only Sensors and the Touch Finder
When only Sensors and a Touch Finder are used, IP addresses are automatically assigned. No settings are
required to use Ethernet.
Connections on Existing Networks
If a Sensor or Touch Finder is connected to a network where a PLC or computer is already connected, the
Ethernet settings must be made compatible with the existing network.
Set the IP addresses with one of the following methods.
● Setting Fixed IP Addresses
• Sensor
(Setup Mode) − [Sensor settings] − [Network] − [Ethernet] − [IP address setting]
1
Press [Fixed].
2
Set the IP address and subnet mask according to the network settings.
Note
• If you connect the Touch Finder or PC Tool to a Sensor on a different network through a router, set fixed IP
addresses.
• When connecting by EtherNet/IP or PROFINET, set fixed IP addresses for the Sensors.
• Touch Finder
(Setup Mode) − [TF settings] − [Ethernet] − [AUTO]
1
Press [OFF].
2
Set the IP address and subnet mask according to the network settings.
● Using a DHCP Server
• Sensor
(Setup Mode) − [Sensor settings] − [Network] − [Ethernet] − [IP address setting]
1
Press [DHCP].
• Touch Finder
(Setup Mode) − [TF settings] − [Ethernet]] − [AUTO]
1
Press [ON].
FQ2-S/CH User's Manual
FQ2-S4
FQ2-CH
59
Setting Up Ethernet