Note
You can specify whether to reflect the judgement result of the judgement conditions for character recognition in the
overall judgement. (The default is to reflect them.)
[Inspect]
[Inspection]
[Reflect]
Step 4 Setting the Verification Conditions
You can register a character string to use to verify that the character string that was read matches the registered char-
acter string. You can register up to 32 character strings for verification in the master data. You can verify the character
string in the inspection against up to 32 character strings that are registered in the master data. The verification result
is saved in an external reference parameter, so you can use a communications command to output it to an external
device.
External Reference Parameters: p. 335
[Inspect]
[Inspection]
1
Press [Verification].
2
Press [Master data regist.].
3
Press the character string to register in the master
data.
4
You can use any of the following three methods to
register character strings in the master data from the
menu display.
[Auto]:
A character string is read from an image and
registered in the master data. The procedure
is essentially the same as the procedure for
teaching in step 2.
[Manual]: A character string is entered directly in the
master data. You can use a software key-
board to register a character string with up to
32 characters.
FQ2-S/CH User's Manual
[Add item.]
[OCR]
[Add item.]
[OCR]
[Details] Tab Page
[Output parameter]
[Settings] Tab Page
Reading and Verifying Character Strings