Measurement Data That Can Be Used for External Outputs and Calculations
The following values can be used as measurement data and output to external devices via the Ethernet or used
in calculations.
Expression text string
Data name
JG
Judgement
DX
Position correction X Amount of correction of X coordinate of
DY
Position correction Y Amount of correction of Y coordinate of
Position correction θ Amount of angle correction θ
DT
X
Measurement coordi-
nate X
Y
Measurement coordi-
nate Y
TH
Measurement angle
SX
Reference coordi-
nate X
SY
Reference coordi-
nate Y
ST
Reference angle
FQ2-S/CH User's Manual
Description
This is the judgement result.
position
position
X coordinate of measurement position
Y coordinate of measurement position
Angle of measurement position
X coordinate of reference position
Y coordinate of reference position
Angle of reference position
Data range
−2: No judgement (not measured),
0: Judgement is OK,
−1: Judgement is NG
−15: Out of range error
−99,999.9999 to 99,999.9999
−99,999.9999 to 99,999.9999
−180 to 180
−99,999.9999 to 99,999.9999
−99,999.9999 to 99,999.9999
−180 to 180
−99,999.9999 to 99,999.9999
−99,999.9999 to 99,999.9999
−180 to 180