Obtaining Multiple Results Simultaneously - Omron FQ2-S Series User Manual

Smart camera
Hide thumbs Also See for FQ2-S Series:
Table of Contents

Advertisement

Parameter
Setting
Correlation
Range: 0 to 100
Defaults: Lower limit: 60, Upper limit: 100
Range: −99,999.9999 to 99,999.9999
Position X
Defaults: Lower limit: −99,999.9999,
Upper limit: 99,999.9999
Range: −99,999.9999 to 99,999.9999
Position Y
Defaults: Lower limit: −99,999.9999,
Upper limit: 99,999.9999
Range: −180 to 180
Angle
Defaults: Lower limit: −180, Upper limit: 180
Count
Range: 0 to 32
Defaults: Lower limit: 0, Upper limit: 32
Note
• You can change the output form for each measurement value to one of the following settings.
] − [Result type] on the right of the display.
[
Press
Absolute value (default): The measured coordinates are output.
Relative value: The difference from the reference position is output as coordinates.

Obtaining Multiple Results Simultaneously

You can detect all items that satisfy the extraction conditions.
Judgement is performed for all detected results.
[Inspect] − [Inspection] − [Shape Search II] − [Modify] − [Details] Tab Page − [Meas.
Parameter]
1
Press [Sorting method] and select the conditions by
which to sort the detected results.
You can output the results in the sort order that you se-
lected.
Note
You can specify the actual output conditions and count for output-
ting multiple results.
Selecting the results to output: p. 161
Selection item
Setting
Sorting method
Corr. ascending order (ascending order of correlation
value)
Corr. descending order (descending order of correlation
value) (default)
Pos.X ascending order (ascending order of position X)
Pos.X descending order (descending order of position X)
Pos.Y ascending order (ascending order of position Y)
Pos.Y descending order (descending order of position Y)
160
Inspecting with the Shape Search II Inspection Item
Description
Adjust the upper and lower limits of the correlation for an OK judge-
ment.
Adjust the upper and lower limits of measurement position X for an
OK judgement.
Adjust the upper and lower limits of measurement position Y for an
OK judgement.
Adjust the upper and lower limits of angle for an OK judgement.
Adjust the upper and lower limits of the detection count for an OK
judgement.
Description
Sorts the results in order from the smallest correlation
to the largest.
Sorts the results in order from the largest correlation to
the smallest.
Sorts the results in order from the smallest measure-
ment X position to the largest.
Sorts the results in order from the largest measure-
ment X position to the smallest.
Sorts the results in order from the smallest measure-
ment Y position to the largest.
Sorts the results in order from the largest measure-
ment Y position to the smallest.
FQ2-S/CH User's Manual