Measurement Data That Can Be Used for External Outputs and Calculations
The following values can be used as measurement data and output to external devices via the Ethernet or used
in calculations.
Expression text string
JG
CR
DV
X
Y
TH
RX
RY
SX
SY
ST
CT
AN
ANX
ANY
DX
DY
CRN[0] to CRN[99]
DVN[0] to DVN[99]
4-17 Calculations and Judgements Using Inspection Item Data: p. 213
172
Inspecting with the Sensitive Search Inspection Item
Data name
Description
Judgement
This is the judgement result of the
sensitive search.
Correlation
Correlation
Deviation
Density deviation
Position X
This is the X coordinate of the position
where the model was found.
Position Y
This is the Y coordinate of the position
where the model was found.
Angle
This is the angle of the position where
the model was found.
Detection X
This is the X coordinate of the detec-
tion point when the model was regis-
tered.
Detection Y
This is the Y coordinate of the detec-
tion point when the model was regis-
tered.
Reference position X
This is the X coordinate of the position
where the model was registered.
(This is the center of the model
region.)
Reference position Y
This is the Y coordinate of the position
where the model was registered.
(This is the center of the model
region.)
Reference angle
This is the angle when the model was
registered.
NG sub-region
This is the number of NG sub-regions. 0 to 100
Sub-region number
This is the number of the regions with
the lowest correlation.
Sub-region number (X)
This is the column number in the X
direction of the output region.
Sub-region number (Y)
This is the row number in the Y direc-
tion of the output region.
Sub-region pos. X
This is the X coordinate of the sub-
region that was found.
Sub-region pos. Y
This is the Y coordinate of the sub-
region that was found.
Correlation (sub-region)
This is the correlation of the sub-
region that was found.
Deviation (sub-region)
This is the density deviation of the
region that was found.
Data range
−2: No judgement (not measured),
0: Judgement is OK,
−1: Judgement is NG,
−13: Teaching not performed error,
−14: Figure not registered error,
−15: Out of range error
0 to 100
Color image: 0 to 221
Monochrome image: 0 to 127
−999,999,999.9999 to
999,999,999.9999
−999,999,999.9999 to
999,999,999.9999
−180 to 180
−999,999,999.9999 to
999,999,999.9999
−999,999,999.9999 to
999,999,999.9999
−999,999,999.9999 to
999,999,999.9999
−999,999,999.9999 to
999,999,999.9999
−180 to 180
0 to 99
0
0
−999,999,999.9999 to
999,999,999.9999
−999,999,999.9999 to
999,999,999.9999
0 to 100
Color image: 0 to 221
Monochrome image: 0 to 127
FQ2-S/CH User's Manual