Menu command
Description
BUSY output
Specifies when to turn OFF the BUSY
signal after starting measurement pro-
cessing.
OUT0 Polarity
You can change the polarity of the output
signals that are assigned to OUT0 to
OUT1 Polarity
OUT2 (regardless of what signal is
assigned to the output).
OUT2 Polarity
BUSY LED
You can change the BUSY indicator to a
RUN indicator.
Output control
You can select the data output method.
(Only when the FQ-SDU1@ is con-
nected.)
Output period
Sets the period for outputting measure-
ment results. (Only when the FQ-SDU1@
is connected.)
GATE ON delay
Sets the time from when the result is out-
put to the parallel interface until the
GATE signal turns ON.
(Only when the FQ-SDU1@ is con-
nected.)
Output time
Sets the time to turn ON the GATE sig-
nal.
(Only when the FQ-SDU1@ is con-
nected.)
Timeout
Sets the timeout time for output control.
(Only when the FQ-SDU1@ is con-
nected.)
Number of delay Set the number of times to ignore the
TRIG signal turning ON between when
the TRIG signal turns ON and the mea-
surement results are output.
(Only when the FQ-SDU1@ is con-
nected.)
ACK signal ON
Sets the output time of the normal execu-
period
tion completion signal for parallel com-
mands.
(Only when the FQ-SDU is connected.)
Output polarity
Sets the ON/OFF polarity for all of the
output signals
(Only when the FQ-SDU is connected.)
Input mode
Specifies whether to use functions other
than scene switching for external parallel
commands.
Output data set
---
Data settings Sets data to output to selected data num-
ber.
Multi-data
setting
Rename
Changes the name of the selected data
number.
Copy
Copies the contents registered in the
selected data number to another data
number.
Delete
Clears the content of the selected data
number.
FQ2-S/CH User's Manual
Setting range
Measurement (default), Data logging,
Image logging, or Result display
Positive (default), Negative
Positive (default), Negative
Positive (default), Negative
BUSY (default), RUN
None (default), Handshaking, or Sync.
Output
2.0 to 5,000.0 ms
10.0 ms (default)
1.0 to 1,000.0 ms
1.0 ms (default)
1.0 to 1,000.0 ms
5.0 ms (default)
0.5 to 120.0 s
10.0 s (default)
1 (default) to 15
1.0 to 1,000.0 ms
5.0 ms (default)
Positive(default), Negative
Standard mode (default) or Expanded
mode
Data 0 to data 31
Text strings for the filter items, position
compensation items, inspection items
and expression that are set
The name can be changed to a name
with up to 15 alphanumeric characters.
Data
Refer-
ence
1
System
---*
1
System
---*
System
System
1
System
---*
1
System
---*
1
System
---*
1
System
---*
1
System
---*
1
System
---*
1
System
---*
1
System
---*
1
System
---*
1
System
---*
1
Scene
---*
Scene
Scene
Scene
Scene
Scene
321
Menu Tables