6.33.5 Open network option

c000 to c119 : Communication option common parameters
c150 to c199 : ProfiBus DP option parameters
c200 to c249 : DeviceNet option parameters
c400 to c449 : EtherCAT option parameters
c500 to c549 : EtherNet common parameters
c550 to c599 : EtherNet/IP option parameters
c600 to c649 : Modbus TCP option parameters
c850 to c899 : EtherCAT option parameters
c900 to c909 : Communication option common parameters
ProfiBus DP option
DeviceNet option
EtherNet / IP-Modbus TCP option (Type: IPE002Z)
EtherCAT option
Refer to each Instruction Manual of option for details.

6.34 Permanent magnet motors

f910 : Step-out detection current level
f911 : Step-out detection time
f912 : q-axis inductance
f913 : d-axis inductance
 Function
If the permanent magnet motor (PM motor) steps out and if the exciting current increases (it increases
in such a case) and remains above the value set with f910 for the period of time set with f911 ,
the inverter will judge the motor to be stepping out and trip it. At that time, the trip message
" sout " is displayed.
(Type: PDP003Z)
(Type: DEV003Z)
(Type: IPE003Z)
F-127