6.18.2 Hit and stop control
382 : Hit and stop control
383 : Hit and stop control frequency
 Function
These parameters are can be used as hit and stop control for material handling smooth deceleration
and stopping is ensured by limit switch.
[Parameter setting]
Title
 Hit and stop control
 Hit and stop control frequency
This function is valid when the parameter f382 = 1 is set.
■ Input terminal settings
Assign the following functions to the input terminal, you can operate the hit and stop control by using the
terminal's ON/OFF.
Input terminal function
140
Forward deceleration
142
Forward stop
144
Reverse deceleration
146
Reverse stop
Each of the following numbers (141, 143, 145, 147) are reverse signals.
<Sample sequence diagram>
F - slow down
R - slow down
Function
Forward operation toward f383 setting
Forward stop
Reverse operation toward f383 setting
Reverse stop
Forward
f383
0
f383
Reverse
Forward
Reverse
F - stop
R - stop
F-55
Adjustment range
0: Disabled, 1: Enabled, 2: -