 Table of output terminal functions 4
Function
Code
No.
144
PIDF
145
PIDFN
146
FLR
147
FLRN
150
PTCA
151
PTCAN
152
STO
153
STON
154
DISK
155
DISKN
156
LI1
157
LI1N
158
LI2
159
LI2N
160
LTAF
161
LTAFN
162
NSA
163
NSAN
166
DACC
167
DACCN
168
DDEC
169
DDECN
170
DRUN
171
DRUNN
11
172
DDC
173
DDCN
174 to 179
*1: Factory specific coefficient parameters are manufacturer setting parameters. Do not change the value of these parameters.
Function
Signal in accordance of frequency command
Inversion of signal in accordance of
frequency command
Fault signal (output also at a retry waiting)
Inversion of fault signal (output also at a
retry waiting)
PTC input alarm signal
Inversion of PTC input alarm signal
Safe torque off signal
Inversion of safe torque off signal
Analog input break detection alarm
Inversion of analog input break detection
alarm
F terminal status
Inversion of F terminal status
R terminal status
Inversion of R terminal status
Cooling fan replacement alarm
Inversion of cooling fan replacement alarm
Number of starting alarm
Inversion of number of starting alarm
Acceleration operation in progress
Inversion of acceleration operation in
progress
Deceleration operation in progress
Inversion of deceleration operation in
progress
Constant speed operation in progress
Inversion of constant speed operation in
progress
DC braking in progress
Inversion of DC braking in progress
Factory specific coefficient
Action
ON: Frequency commanded by  and  are
within ±.
OFF: Other than those above
Inversion of PIDF
ON: While inverter is tripped or retried
OFF: While inverter is not tripped and not retried
Inversion of FLR
ON: PTC thermal input value is f646 or more
OFF: PTC thermal input value is less than f646
Inversion of PTCA
ON: Safe torque off signal output
OFF: Other than those above
Inversion of STO
ON: VIB terminal input value is f633 or less
OFF: VIB terminal input value is more than f633
Inversion of DISK
ON: F terminal is ON status
OFF: F terminal is OFF status
Inversion of LI1
ON: R terminal is ON status
OFF: R terminal is OFF status
Inversion of LI2
ON: Cooling fan reaches parts replacement time
OFF: Cooling fan does not reach parts replacement time
Inversion of LTAF
ON: Number of starting alarm is f648 or more
OFF: Number of starting alarm is less than f648
Inversion of NSA
ON: Acceleration operation in progress
OFF: Other than those above
Inversion of DACC
ON: Deceleration operation in progress
OFF: Other than those above
Inversion of DDEC
ON: Constant speed operation in progress
OFF: Other than those above
Inversion of DRUN
ON: DC braking in progress
OFF: Other than those above
Inversion of DDC
-
K-38
E6581697
Reference
6.3.4
6.20
6.15.3
6.24.16
9.3
6.24.14
7.2.2
6.24.15
6.24.17
7.2.2
6.8.1
*1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents