Toshiba TOSVERT VF-MB1 Instruction Manual page 305

Industrial inverter for 3-phase induction motors
Hide thumbs Also See for TOSVERT VF-MB1:
Table of Contents

Advertisement

Communication
Title
Function
No.
0614
Ground fault

detection selection
0615
Over-torque

trip/alarm
selection
0616
Over-torque

detection level
0618
Over-torque

detection time
0619
Over-torque

detection
hysteresis
0620
Cooling fan

ON/OFF control
0621
Cumulative

operation time
alarm setting
0626
Over-voltage stall

protection level
0627
Undervoltage

trip/alarm
selection
0631
Inverter overload

detection method
0632
Electronic-thermal

memory
0633
Analog input

break detection
level (VIC)
0634
Annual average

ambient
temperature (parts
replacement
alarms)
0644
Operation

selection of
analog input break
detection (VIC)
0645
PTC thermal

selection
0646
PTC detection

resistor value
0648
Number of starting

alarm
0649
Fallback

frequency
0650
Forced fire-speed

control selection
0656
Factory specific

coefficient 6A
*2: Default setting values vary depending on the capacity. Refer to section 11.4.
*3: Factory specific coefficient parameters are manufacturer setting parameters. Do not change the value of these parameters.
Minimum
setting unit
Unit
Adjustment range
Panel/Commun
ication
-
-
0: Disabled
1: Enabled
-
-
0: Alarm only
1: Tripping
%
1/0.01
0 (disabled)
1-250
s
0.1/0.1
0.0-10.0
%
1/1
0-100
-
-
0: ON/OFF control
1: Always ON
100
0.1/0.1
0.0-999.0
hours
(=10 hours)
1/1
100-150
%
-
-
0: Alarm only
(detection level 64% or less)
1: Tripping
(detection level 64% or less)
2: Alarm only
(detection level 50% or less, input
AC reactor required)
-
-
0: 150%-60s (120%-60s)
1: Temperature estimation
-
-
0: Disabled
1: Enabled
%
1/1
0: Disabled,
1-100
-
-
1: -10 to +10C
2: 11-20C
3: 21-30C
4: 31-40C
5: 41-50C
6: 51-60C
-
-
0: Tripping
1: Alarm only (Coast stop)
2: Alarm only (f649 frequency)
3: Alarm only (Maintain running)
4: Alarm only (Deceleration stop)
-
-
1: Tripping
2: Alarm only
1/1
100-9999
10000
0.1/0.1
0.0-999.0
times
Hz
0.1/0.01
ll-
-
-
0: Disabled
1: Enabled
-
-
-
K-17
E6581697
Default
User
Reference
setting
setting
1
6.24.9
0
6.24.10
150
0.5
10
0
6.24.11
876.0
6.24.12
*2
6.15.4
6.15.5
0
6.24.13
0
3.5
0
3.5
6.24.1
0
6.24.14
3
6.24.15
0
6.24.14
1
6.24.16
3000
999.0
6.24.17
0.0
6.24.14
0
6.25
-
* 3
11